Daewoo DWB-052C Use & Care Manual Download Page 5

5

• FAN & COOLING CONTROL

The Fan Control Selector Switch has five positions.
Choose one of the speed settings by rotating the fan control Selector Switch to the appropriate position.

OFF

Select this setting for stop all operation of air conditioner

HIGH FAN

Select this setting for maximum air circulation without cooling.

LOW FAN

Select this setting for quiet air circulation without cooling.

HIGH COOL

Select this setting for cooling operation with HIGH FAN.

LOW COOL

Select this setting for cooling operation with LOW FAN.

• TEMPERATURE CONTROL

Choose a temperature settings by rotating the knob of thermostat to the appropriate position

• The Thermostat automatically starts and stops cooling operation in

order to keep the room temperature at a proper level, and this results in
efficient use of power and economical cooling.

• Turn clockwise for a cooler room temperature.
• Turn counter-clockwise for a warmer room temperature.

OPERATING INSTRUCTIONS

NOTE

• FOR MOST ECONOMICAL USE

1. Properly control the room temperature.

2. Avoid the unit being exposed to direct sunlight. Keep direct sunlight from the room.

3. Do not leave doors and windows open.

NOTE

Setting the control at the coldest extreme of the temperature range will not cool the room any
faster. Usually the midpoint is a good starting position. If the room temperature is not satisfactory
after a reasonable period of time, adjust the temperature control to a lower or higher.

Selector

Off

Low

Cool

Low

Fan

High
Cool

High

Fan

Thermostat

Cooler

CAUTION

When the air conditioner has been performing its cooling operation and is turned “OFF” or set to the

‘FAN” position, wait at least 3 minutes before resetting to the cooling operation.

Summary of Contents for DWB-052C

Page 1: ...se damage to the unit 8 If the air conditioner is operated without an air filter dust is not removed from the air and resultant accumulation in the unit may lead to a failure Do not forget to install...

Page 2: ...NG AIR FLOW DIRECTION AIR FLOW AROUND UNIT 6 CARE AND MAINTENANCE 7 AIR FILTER CLEANING THE AIR CONDITIONER 7 ELECTRICAL REQUIREMENTS 8 ELECTRICAL GROUNDING INSTRUCTIONS USE OF EXTENSION CORDS 8 BEFOR...

Page 3: ...d as shown in Fig 1 For proper drainage Rear side of the unit should be inclined about 5mm lower 4 Insert unit in window With 2 people lift unit and insert it into the window opening 5 Finish opening...

Page 4: ...MAJOR COMPONENTS NO PART NAME 1 CABINET 2 BLADE VERTICAL 3 COOL AIR DISCHARGE 4 GRILLE FRONT 5 KNOB THERMOSTAT NO PART NAME 6 KNOB SELECTOR 7 AIR INTAKE 8 AIR FILTER 9 CONTROL PANEL DWB 052C 2 3 8 6...

Page 5: ...a proper level and this results in efficient use of power and economical cooling Turn clockwise for a cooler room temperature Turn counter clockwise for a warmer room temperature OPERATING INSTRUCTIO...

Page 6: ...eck in door grill and outdoor louvers for air flow obstructions Do not block air flow to and from unit The outdoor coil should be checked and periodically cleaned for debris that may collect and block...

Page 7: ...detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliances 6 Condenser and Evaporator coils should be cleaned at the beginn...

Page 8: ...d rating of the extension cord set should be 250V 10A Min The socket outlet shall be installed near the equipment and shall be easily accessible REPLACEMENT OF SUPPLY FLEXIBLE CORD If the supply flexi...

Page 9: ...aces Normal for operation in humid areas Suggested Solution Set Fan Control Select to position other than OFF Confirm power cord is plugged in Verify main power switch main circuit breaker or fuse of...

Page 10: ...ARE MANUAL WINDOW TYPE ROOM AIR CONDITIONER W1 Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult your dealer for help or...

Reviews: