background image

4

1. SAFETY

Read and understand this user guide before using the equipment. Retain the user guide for future 
reference.
Any damage or equipment failure due to incorrect usage is not covered by warranty.
• Always wear approved safety goggles when working with tools and equipment.
• When inflating tyres etc, do not exceed the pressures recommended by the manufacturer.
• Do not submerge the device as damage to the unit may occur.
• Always monitor inflation to avoid over-inflation or bursting of the inflated item.
• If inflation time exceeds 3 minutes be aware that some parts of the device may become hot.

Overview and Controls

The product is designed for general domestic inflation tasks, and includes additional functions:
• Standard vehicle 12VDC charging (charging cable / adaptor included).
• Programmable inflation pressure - automatically stops when required pressure is reached (Schra-
der type
plus 3 additional valve adaptors included).
• Charging/powering USB devices.
• Battery charge indicator.
• Torch function.

2. OPERATION

Note:

 Before use, ensure that all parts have been supplied and the battery is fully charged. Initial 

charge may take up to 48 hours.

Charging the Battery

1. Connect the supplied charging cable to a standard 12VDC vehicle socket.
2. Connect the other end of the cable to the compressor Charging Connector.
3. When charging, the Battery Level Indicator flashes.
4. When fully charged, all 4 indicator lights will illuminate and remain on.

Using the Compressor for Inflation

1. Unclip the Air Hose from the unit. Unlock and securely connect the Valve Adaptor to the valve of 
the item to be inflated (X), then lock the adaptor. If required, attach the necessary adaptor into the 
Valve Adaptor.
2. Press the Inflation ON / OFF button to turn the unit on.
3. Press the Increase Pressure / Decrease Pressure buttons as required until the desired pressure is 
shown in the Display. If required, press the
Pressure Unit button to change the unit of measurement between PSI,
Bar, KPa and kgf.
4. Press the Increase Pressure / Decrease Pressure buttons simultaneously to save the pressure 
setting.
5. Press the Inflation ON / OFF button to turn the compresor on. When the pressure is reached, the 
compressor automatically stops. Disconnect the Valve Adaptor quickly from the inflated item to 
avoid pressure loss. The unit will switch off automatically after 15 seconds.

Using the Torch / Flashlight

1. Press and hold the Torch / USB Charging button for 3 seconds to switch the torch light on.
2. When finished, press the Torch / USB Charging button once to switch the torch light off.

Using the USB Charger

1. Connect the USB device to the USB Connector using a standard USB cable (not supplied). The 
battery must be charged to use this function.
2. Press the Torch / USB Charging button once to switch the USB charging function on. If the unit 
has been used within the last 48 hours, USB charging is automatic on conneciton of the cable - no 
need to press the Torch / USB Charging button.
3. When finished, disconnect the USB cable from the USB Connector.

Fault Indicator

The Fault Indicator may illuminate if the unit reaches an over-temperature or over-current state. 
When in a fault state all functions are not available. When the indicator is off, the unit can be used 
again.

3. TECHNICAL SPECIFICATIONS

Max pressure: 10.3 atm
Current consumption (in work): 4~7 A
Current consumption (sleep mode): <50 A
Flashlight: <150 mA / USB: < 1.5 A
USB output: 5 V/max: 1 A
Charger voltage: 9~30 V
Charger current: < 2 A
Battery capacity: 3000 mAh

Torch

+

-

USB

+

-

Summary of Contents for DW150Li

Page 1: ...Manufactured under license of Daewoo International Corporation Korea www daewoopowerproducts com USER S MANUAL DW150Li Lithium car air compressor ...

Page 2: ...INDEX 1 SAFETY 2 2 OPERATION 3 3 TECHNICAL SPECIFICATIONS 4 WARRANTY 5 1 ...

Page 3: ...s etc do not exceed the pressures recommended by the manufacturer Do not submerge the device as damage to the unit may occur Always monitor inflation to avoid over inflation or bursting of the inflated item If inflation time exceeds 3 minutes be aware that some parts of the device may become hot Overview and Controls The product is designed for general domestic inflation tasks and includes additio...

Page 4: ... item to be inflated X then lock the adaptor If required attach the necessary adaptor into the Valve Adaptor 2 Press the Inflation ON OFF button to turn the unit on 3 Press the Increase Pressure Decrease Pressure buttons as required until the desired pressure is shown in the Display If required press the Pressure Unit button to change the unit of measurement between PSI Bar KPa and kgf 4 Press the...

Page 5: ...en used within the last 48 hours USB charging is automatic on conneciton of the cable no need to press the Torch USB Charging button 3 When finished disconnect the USB cable from the USB Connector Fault Indicator The Fault Indicator may illuminate if the unit reaches an over temperature or over current state When in a fault state all functions are not available When the indicator is off the unit c...

Page 6: ...or more nodes teaser on the surfaces of the cylinder and the piston or destruction of piston rings Also the warranty does not cover failure of the automatic voltage regulator due to incorrect operation Failure caused by clogging of the fuel and cooling systems Wearing parts carbon brushes belts rubber seals oil seals shock absorbers springs clutches spark plugs mufflers nozzles pulleys guide rolle...

Page 7: ...www daewoopowerproducts com Manufactured under license of Daewoo International Corporation Korea ...

Reviews: