14
PROBLEM
CHECK POINT
CAUSE
SOLUTION
There is leak-
age during
spinning.
Is the Bellows Assembly properly
assembled?
The Waterseal or the
Oilless Metal in the Bellows
Assembly is worn out.
Replace Bellows
Assembly.
Waterproofing not working
due to defective assembly.
Re-assemble
Bellows Assembly.
YES
NO
YES
YES
Basket Spin
does not
stop with the
Door Spin
open
The Brake Band touches the
Drum Coupling when the Door
Spin open.
Brake Band is worn out.
Defective
Door Switch
Is the electric connection of the
Door Switch good?
Replace
Door Switch
The contact of the Door
Switch does not open due
to deformity of the lever of
Door Switch.
Replace Door Switch or
reshape the lever of Door
Switch.
Replace Brake Band or
Brake Fix Assembly.
Brake wire is too short.
Replace after loosening
LINK BRAKE and adjusting
upward.
NO
NO
C o n c e r n i n g D r a i n a g e ( P u m p )
PROBLEM
Drainage is
not satisfac-
tory
CHECK POINT
CAUSE
SOLUTION
PROBLEM
CHECK POINT
CAUSE
SOLUTION
Is the height of the drainage area where
the Drain Hose hangs over 1m?
The Drain Hose is too high.
Hang the Drain Hose lower.
Are there impurities on the Drain
Strainer?
YES
NO
NO
Impurities are obstructing
drainage.
Remove out impurities on
the drain Strainer
Impurities are obstructing
drainage.
Are there impurities in the Valve
Housing or Inlet Joint?
Remove impurities or
replace Valve Housing or
Inlet Joint.
Impurities are blocking the
Drain Hose
Remove impurities
YES
YES
NO