25
5.OCP (OVER CURRENT PROTECTION) CIRCUIT
This circuit is designed to protect the circuit from over current due to overload occurred at the rear of 132[V]
line.
1) CONFIGURATION OF OCP CIRCUIT
2) EXPLANATION OF THE OPERATION
¤
There is very little voltage drop at
£
R821(1W 0.68) of 123 [V] line.
¤Ł
In case that the overload occurs at the rear of 123[V] line, the increase of the voltage drop at R821 bring
down the base voltage of the Q806 so as to drive the Q806
¤Ø
Because of the overload at the rear of the R821, the voltage of the
£
point decreases. And this makes Q806
turn on so that a voltage is applied to the #29 of I701.
¤Œ
In case that OCP operates by the #29 of the I701, the set is protected by power off (#32 of I701
¡
LOW).
+
C816
100µ
16V
R821
123 [V] LINE
1W 0.68(F)
R820
22K
1/4W
R823
8.2K
1/4W
C815
4.7µ
50V
Q806
KSA1013Y
R822
20K
1/4W
R826
20K
1/4W
D810
UZ-5.1
R824
22K
1/4W
I701 #29
(OCP)
FBT
A
C
B