OUTDOOR CONDITIONS
Indoor
Conditions
12°C D
11°C W
7°C D
6°C W
4°C D
3°C W
0°C D
-1°C W
-4°C D
-6°C W
-7°C D
-8°C W
Capacity
kW
4.81 4.28
3.78 2.45
2.04
1.97
15°C
Input kW.
1.61
1.44
1.29
1.11
1.03
0.99
Capacity
kW
4.53 4.06
3.66 2.32
2.14
1.98
18°C
Input
kW.
1.65 1.44
1.31 1.18
1.14
1.02
Capacity kW
4.50
4.10
3.63 2.21
1.98
1.94
20°C
Input kW.
1.69
1.48
1.34 1.18
1.12
1.03
Capacity
kW
4.20 3.99
3.46 1.87
2.00
1.87
22°C
Input
kW.
1.78 1.48
1.35 1.12
1.13
1.07
5.7 DSB-G185L
SUMMER
WINTER
OUTDOOR TEMPERATURE DRY
Indoor
Conditions
25°C 30°C 35°C 40°C 45°C
50°C
Total capacity kW
4.69
4.45
4.15
3.81
3.50
3.27
Sensitive capacity kW
3.28
3.18
3.04
2.88
2.74
2.62
21°C D
15°C W
Input
kW.
1.70 1.84
1.99 2.14
2.28
2.43
Total capacity kW
5.03
4.81
4.53
4.25
3.97
3.73
Sensitive capacity kW
3.47
3.37
3.25
3.13
3.04
3.00
24°C D
17°C W
Input
kW.
1.70 1.86
2.02 2.17
2.33
2.50
Total capacity kW
5.38
5.28
5.00
4.61 4.20
3.83
Sensitive capacity kW
3.77
3.69
3.55
3.38 3.20
3.06
27°C D
19°C W
Input kW.
1.73
1.90
2.05
2.22 2.38
2.54
Total capacity kW
5.68
5.57
5.49
5.30
5.06
4.81
Sensitive capacity kW
3.57
3.61
3.58
3.52
3.48
3.50
32°C D
23°C W
Input
kW.
1.72 1.91
2.10 2.29
2.48
2.67
14
Summary of Contents for DSB-G075L
Page 3: ...1 Features 1 1Compact design 1 2LED display 2 ...
Page 6: ...3 Dimensions 3 1 Indoor unit DSB G075L DSB G075LH DSB G095L DSB G095LH DSB G125L DSB G125LH 5 ...
Page 7: ...DSB G185L DSB G185LH 6 ...
Page 9: ...3 6 Outdoor unit DSB G185L DSB G185LH 110 62 8 ...
Page 10: ...4 Refrigeration cycle diagram 9 ...
Page 17: ...16 ...
Page 18: ...6 2 Wiring diagram 6 2 1 Cooling only 6 2 1 1 DSB G075L DSB G095L DSB G125L 17 ...
Page 20: ...6 2 2 Heating cooling 6 2 2 1 DSB G075LH DSB G095LH DSB G125LH INDOOR UNIT OUTDOOR UNIT 19 ...
Page 25: ...24 ...
Page 26: ... C 25 ...
Page 28: ... C C C C C C C C C C C C C C C C DSB G075L DSB G075LH DSB G095L DSB G095LH 27 ...
Page 29: ...0 0 0 0 DSB G125L DSB G125LH DSB G185L DSB G185LH 28 ...
Page 30: ...29 ...
Page 31: ...30 ...
Page 32: ...31 ...
Page 33: ... C C 32 ...