This Installation section explains how and where to connect this new air conditioner. Please read make sure all acces-
sories are included as shown below and read manual thoroughly. This Installation section is provided to assist the per-
son knowledgeable in air conditioner installation and should not be installed by anybody who is not thoroughly familiar
with this type of installation. Please contact a professional installer if necessary.

ACCESSORIES SUPPLIED WITH THE UNIT:

COPPER TUBING:

Copper tubing supplied is available at most dealers or A/C shops. Make sure the new copper tubing has the exact same
specifications and diameter as the original copper tubing and is as short as possible.

BASIC ACCESSORIES

3

ON

OFF

ENTER CANCEL

TIMER

RESET

SWING

FAN SPEED

MODE

SLEEP

ON/OFF

TEMP.

1

2

8

6

7

9

3

10

11

12

5

4

No.

Description

Qty.

1

Wall Bracket

1

2

Outdoor Unit Cover

1

3

Remote Controller

1

4 Deodorizing 

Filter 

1

5 Electrostatic 

Filter 

1

6

Remote Holder

1

No.

Description

Qty.

7

Foot Cushion

4

8

Concrete Nails

5

9

Remote Holder Screws

3

10

Wall Bracket Screws

8

11

Wall Cap

2

12

Battery

2

Summary of Contents for DSB-181L

Page 1: ...MODEL DSB 181L 181LH OWNER S MANUAL SPLIT AIRCONDITIONING SYSTEM S1 ...

Page 2: ...unit s weight A frame may be necessary for added support When installing in a room make sure the tubes are well insulated to protect the walls and furniture from sweating of the tubes When installing in moist or uneven locations make sure to use a raised level concrete pad or concrete blocks to provide a level solid foundation for the out door unit this prevents water damage and vibration When ins...

Page 3: ...eries 9 Setting the Unit for Remote Operation 9 Celsius to Fahrenheit Conversion Chart 10 To Set Auto Mode 10 To Set Quick Mode 11 To Set Cool Mode 11 To Set Fan Only Mode 12 To Set Dehumidifier Mode 12 To Set Unit to Heat Mode DSB 181LH Only 13 To Select the Fan Direction 13 To Set On Timer Mode 14 To Set Off Timer Mode 14 To Set Sleep Mode 15 To Set Turbo Mild Mode 15 Emergency Operation 15 Chan...

Page 4: ...ESSORIES SUPPLIED WITH THE UNIT COPPER TUBING Copper tubing supplied is available at most dealers or A C shops Make sure the new copper tubing has the exact same specifications and diameter as the original copper tubing and is as short as possible BASIC ACCESSORIES 3 ON OFF ENTER CANCEL TIMER RESET SWING FAN SPEED MODE SLEEP ON OFF TEMP 1 2 8 6 7 9 3 10 11 12 5 4 No Description Qty 1 Wall Bracket ...

Page 5: ... 1 ID19 6 X 2m PVC Pipe 2 Tape 2TQ1008000 1 PVC 80W X 0 1T X 3 5m 3 Copper Tubing Extension 3100002600 1 1 2 1 4 Copper Tube 4 Insulator Plate 3103301000 1 F US 225 X 120 X 8T 5 Putty 2221040001 1 80g 6 Connection Cord 3102796400 1 3P X 6m 7 Signal line Cord 3102796500 1 3P X 6m Complete Optional 3100400000 1 Accessories 1 2 3 4 5 6 7 DSB 181LH Only ...

Page 6: ...r Cleaning Filters Removes dust and prohibits germs AIR OUT Air In Sensor Wire DSB 181LH Only Fan Direction Up Down Fan Direction Left Right ON OF F EN TE R CA NC EL TIM ER RE SE T FA N DIR FA N SP EE D MO DE SL EE P ON OF F TE MP LCD Remote Controller INDOOR UNIT Connection Cover Remove cover to access the AC connection to the indoor unit Service Valves The indoor and outdoor units are connected ...

Page 7: ...ergency button EMERGENCY to operate by hand Open the front panel on emergency operating Remocon switch is usually used with remote con troller Indoor Unit Display Switch Panel ON Red Lights on during the operation Air clean Green Lights on during the operation Timer Green Lights on during the time of reservation mode Quick Green Lights on during the time of Quick Mode TIMER QUICK AIR CLEAN ON EMER...

Page 8: ...t right direction for fan ON OFF Button Press to turn the unit on or off TEMPERATURE Buttons Press to raise or lower the desired temperature FAN SPEED Button Press to select the fan speed High Middle Low Natural COVER Slide down to access most of the remote buttons Slide down further to access the battery compartment AUTO REMOTE CONTROLLER MODE Indicators Auto Quick Cool Fan Dehumidifier Lights to...

Page 9: ...on for fan ON OFF Button Press to turn the unit on or off TEMPERATURE Buttons Press to raise or lower the desired temperature FAN SPEED Button Press to select the fan speed High Middle Low Natural COVER Slide down to access most of the remote buttons Slide down further to access the battery compartment AUTO FAN DIR FAN DIR REMOTE CONTROLLER MODE Indicators Auto Quick Cool Fan Dehumidifier Heat Lig...

Page 10: ...ry leakage 5 Do not try to recharge batteries not intended to be recharged they can overheat and rupture Follow battery manu facturer s directions HOW TO INSTALL BATTERIES To install the batteries follow the procedures below Plug into 220V 240V AC Outlet 1 Slide down the cover to access most of the remote buttons Slide down further to access the battery compartment 2 Insert two AAA size Alkaline b...

Page 11: ...utton on the remote control to turn the unit on the On LED will light on the indoor unit and ON will light in the remote display 2 Make sure the AUTO indicator appears in the remote display Using the TEMP or buttons set the desired temperature The desired temperature can be changed up or down 1 degree from the actual room temperature For temperature setting 24 28 C AUTO 3 Then the unit will automa...

Page 12: ...t and ON will light in the remote display 2 Press the MODE button until the Cool indicator appears in the display 3 Using the TEMP or buttons set the desired temperature The desired temperature can be changed up to 32 C and down to 18 C 4 To select the fan speed press the FAN SPEED button until the desired speed appears in the display see below FAN SPEEDS AUTO The fan will automatically select the...

Page 13: ... low speed The fan will operate on medium speed The fan will operate on high speed NATURAL The fan will randomly cycle through the speeds simulating a breeze NOTE If NATURAL is selected the NATURAL indicator on the indoor unit will light 1 Press the ON OFF button on the remote control to turn the unit on the On LED will light on the indoor unit and ON will light in the remote display 2 Press the M...

Page 14: ...ired temperature can be changed up to 32 C and down to 18 C 4 To select the fan speed press the FAN SPEED button until the desired speed appears in the display see below NOTE When the heating orperation is started hot air deliv ery might be delayed due to warm up period FAN DIR The air will flow up First Press and down Second Normal air direction Press 1 Press the ON OFF button on the remote contr...

Page 15: ...E Press the ENTER button within 5 seconds of selecting the desired time If mote than 5 seconds elapse steps 3 and 4 must be repeated 2 Press the TIMER OFF button once to enter the Timer screen 1 Press the ON OFF button of timer on the remote control to set the off timer mode HOUR and OFF on the remote display will be dis played and TIMER will be flicked When you increase to press ON OFF you will g...

Page 16: ...t 1 Open the indoor unit s cover and make sure the EMERGENCY REMOTE switch is set to the EMER GENCY position TEST EMERGENCY REMOTE Switch 3 To turn the unit off slide the EMERGENCY REMOTE switch to the REMOTE position 2 The unit will then turn on and depending on the room temperature it will select the cool or dehumidifier mode fan speed and fan direction automatically EMERGENCY OPERATION If the r...

Page 17: ...adequate 5 Insert cleaned or new black filters back into the unit 4 Insert cleaned or new small filters Deodorizing and Electrostatic back into the unit CLEANING THE INDOOR COVER To clean the indoor cover follow the procedures below 1 Remove the left and right side to open the indoor cover upward by two hands NOTE Please remove and insert the indoor cover by two hands 2 Pushing forward the indoor ...

Page 18: ...ry important to protect this unit BEFORE THE SEASON Make sure the air filters are clean Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions Make sure the unit is grounded Consult a serviceman for help PRECAUTIONS Do not use this unit for animal or plant storage In a lightning or thunder storm immediately unplug it from the wall warning Make sure the AC co...

Page 19: ...o heat air at heating If the unit is turned off and then Wait 3 minutes for the unit to operate immediately back on the compressor will delay for 3 minutes The air filter s is dirty or clogged Clean or replace filter s A door or window is open Shut door or window There is an obstacle in front of Remove obstacle intake or indoor unit The temperature has been set Check and reset if necessary imprope...

Page 20: ...H 322 x D 205 mm Outdoor Unit Dimensions W 800 x H 615 x D 277 mm Net Weight Indoor 11 7 kg 11 7 kg Outdoor 50 kg 51 9 kg Connection Type Flare the piping Gas 1 2 12 7 mm Liquid 1 4 6 35 mm Air Cleaning Anti bacteria Filter Electrostatic Filter Deodorizing Filter Operating Indoor side Heating Mode min 21 C max 32 C min 15 C max 27 C Condition Outdoor side Heating Mode min 21 C max 50 C min 21 C ma...