50
1
INDOOR UNIT
PROCEDURES PHOTOS
1. Stop the Air conditioner and disconnect the power cord from the wall
outlet.
2. Removing the insert Grille and Frame Grille. (Fig 1~2)
!
Draw up the insert Grille and remove it.
@
Loosen two special screw for fixing the Cover Ter-Block.
#
Loosen three screw at the Body.
$
Remove the Frame.
3. Removing the Control Box. (Fig 3)
!
Remove room and coil thermistors.
@
Disconnect the fan motor lead wire from connection at the
Control PCB.
#
Disconnect the stepping motor lead wire from connection at the
Control PCB.
$
Remove the select switch from connection at the Control PCB.
%
Loosen a screw for fixing ground wire.
^
Remove the Control Box
4. Removing the Drain Pan. (Fig 4)
!
Disconnect the Body drain hole. (left and right Body)
@
Disconnect three hook and remove the Drain Pan.
5. Removing the Indoor Coil. (Fig 5~6)
!
Remove three screw for fixing indoor Coil at the Body.
@
Remove the hook for fixing Bracket Pipe at the Back side Body.
#
Remove Indoor Coil.
6. Removing the Cross Flow Fan. (Fig 7)
!
Remove set screw for fixing Motor shaft.
@
Remove Cross Flow Fan.
7. Remove Motor FCU and Bearing Plastic.
10. DISASSEMBLY INSTRUCTIONS
Fig 2
Fig 1
Fig 3
Fig 4
Fig 5
Fig 6
Fig 7
¡
DSB-090L/DSB-120L/DSA-100L/DSA-120L