5. REFRIGERANT CYCLE
INDOOR UNIT
Evaporator
Cross flow fan
Connecting pipe
Capillary tube
Dryer
Condenser
Propeller fan
OUTDOOR UNIT
Refrigerant flow
Service valve
Service valve
Accumulator
Compressor
Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter.
Contents
Model Name
Capillary Tube
Charge Quantity
DSA-101L
IDØ1.6 x ODØ3.2 x 600L
1,150 g
DSA-121L
IDØ1.6 x ODØ3.2 x 600L
1,200 g