![Daewoo DPP-32F1BMB Service Manual Download Page 8](http://html1.mh-extra.com/html/daewoo/dpp-32f1bmb/dpp-32f1bmb_service-manual_3258610008.webp)
-8-
The Feature of Inside
3-3. Power Specification
1) Input and Environmental Requirement
2) Output Characteristics
3. Connector
Output
Name
Output
Typical
(V)
Variable
Voltage
Range(V)
Voltage
Tolerance
(%)
Output Current(A)
Ripple & Noise
(mVp-p)
Min.
Typical
Max.
STBY5V
5.0
-
0
1.2
1.7
100mVp-p
5Vsc
5.0
-
0.1
0.7
1.7
200mVp-p
9Vsc
9
-
c0
0.3
0.5
200mVp-p
16Vsc
16
-
1
c0.03
1.3
2.2
500mVp-p
Environment Requirement
Description
Operating Temperature Range
0 to 55 Deg.
Operating Humidity Range
10 to 90%
Storage Temperature Range
-20 to 70 Deg.
Cooling system
Convection
Input Requirement
Description
Nominal Input Voltage
AC100V to AC240V
Input Voltage Variation Range
AC90V to AC264V
Nominal Frequency
50 /60 Hz
Frequency Variation Range
47Hz to 63Hz
Inrush Current
50A peak MAX.
NO.
YW396-09V
SMW250-15
1
5V
AC-DET
2
GND
RL_ON
3
Va
VS_ON
4
GND
5V_MNT
5
GND
M5V_ON
6
GND
GND
7
NC
GND
8
Vs
16Vsc
9
Vs
16Vsc
10
GND
11
9Vsc
12
GND
13
5Vsc
14
STBY5V
15
GND
P812
P814