background image

14

1. Economy mode can be selected on auto mode, cool,

mode, dehumidifier mode

Press "economy" button to use economy mode while
the unit turn on

ECONOMY MODE

- MAIN CONTROL IS ONLY AVAILABLE

Select by pressing "economy" button

2. Economy mode is to avoid excessive cooling and ac-

cordingly save electricity by adjusting temperature ir-
recognizably during operation
If you press "economy" button again, the unit return to
previous condition

1. Mild mode can be selected on auto mode, quick

mode, cool mode, fan mode, dehumidifier mode, heat
mode

Press "turbo/mild" button to use mild mode while the
unit turn on

MILD MODE

- REMOTE CONTROLLER IS ONLY AVAILABLE

Select by pressing "TURBO/MILD" button

2. Mild mode is to reduce sound level of air from the fan

and accordingly gives you more silent and comfort-
able room condition.

If you press "turbo/mild" button again, the unit return
to previous condition (turbo mode)

Summary of Contents for DPB-280L

Page 1: ...DOOR UNIT COVER 6 ON OFF 7 TO SET TEMPERATURE 7 TO SELECT THE FAN SPEED 8 TO SELECT THE FAN DIRECTION 9 TO SET THE TIMER MODE 9 TO SET THE FUNCTION MODE 11 AUTO MODE 11 QUICK MODE 11 COOL MODE 12 FAN MODE 12 DEHUMIDIFIER MODE 13 HEAT MODE 13 ECONOMY MODE 14 MILD MODE 14 CLEANING THE AIR FILTER 15 CARE AND MAINTENANCE 16 TROUBLESHOOTING GUIDE 17 SPECIFICATIONS 18 ...

Page 2: ... In case of falling it may cause serious trouble and damage INDOOR UNIT MAIN CONTROLS REMOTE SENSOR LCD REMOTE CONTROLLER Operative distance is within 7m from the indoor unit Use toward to the remote sensor AIR OUT According to the operation mode it is opened closed automatically AIR IN It is to suck warm air There is an air filter inside this grille The method to open the air suc tion grille Pull...

Page 3: ...CONOMY MODE BUTTON ON OFF BUTTON Whenever you push this button It repeats on off on off AUTO FAN SPEED INDICATOR FAN SPEED INDICATOR COOL MODE INDICATOR QUICK MODE INDICATOR HEAT MODE INDICATOR ONLY HEAT PUMP MODEL MILD MODE INDICATOR DEHUMIDIFIER MODE INDICATOR FAN SPEED BUTTON AUTO LOW MIDDLE HIGH NATURAL TEMPERATURE BUTTONS Each time you push this button temperature goes up by 1 C Each time you...

Page 4: ...ton Press to select left right direction for fan ON OFF Button Press to turn the unit on or off TEMPERATURE Buttons Press to raise or lower the desired temperature FAN SPEED Button Press to select the fan speed Auto High Middle Low Natural COVER Slide down to access most of the remote buttons Slide down further to access the battery compartment AUTO FAN DIR FAN DIR MODE Indicators Auto Quick Cool ...

Page 5: ...gram below ON OFF TIMER ENTER CANCEL TURBO MILD BATTERY PRECAUTIONS The precautions below should be followed when using batteries in this device 1 Use only the size and type of batteries specified 2 Be sure to follow the correct polarity when installing the batteries as indicated in the battery compartment Reversed batteries may cause damage to the device 3 Do not mix different types of batteries ...

Page 6: ... neces sary to buy separately when installing the unit The standard power supply of this unit is 220v single phase Use an electricity leakage interrupter if not may cause trouble REMOVE OUTDOOR UNIT COVER Make sure to remove the outdoor cover before operating Otherwise it may bring dam age to the unit 220V ON NOTE Compressor protecting function In normal operation there is a time delay of three mi...

Page 7: ...MPERATURE 26 C NOTES How to change desired temperature on auto mode If you want to change desired temperature you can set temperature to 24 C 28 C from first desired tempera ture 26 C by pressing temperature button TO SET TEMPERATURE METHOD BY USING MAIN CONTROL 1 Adjustment of desired temperature is possible during auto cool dehumidider and heat mode operation 2 The scope of temperature adjustmen...

Page 8: ... 2 SET DESIRED TEMPERATURE 22 C BY USING TEMPERATURE BUTTON If room temperature reach desired temperature the unit repeats cool and fan mode automatically to keep desired temperature NOTES If you select auto fan speed on auto cool dehumidifier and heat mode fan speed will change automatically accord ing to the temperature If natural fan speed is selected led display of fan speed changes low high l...

Page 9: ...s ON OFF you will get desired time Then if pressing ENTER CAN CEL button OFF TIMER Mode will be started If you want to stop OFF TIMER Mode please press ENTER CANCEL again TO SET OFF TIMER MODE This unit can be set to automatically turn off after a predetermined amount of hours up to 24 in the order of 0 5 1 1 5 2 2 5 3 4 5 6 8 10 12 16 20 24 AUTO 3 Repeatedly press the TIMER OFF button until the d...

Page 10: ...u will get desired time Then if pressing ENTER CANCEL button ON TIMER Mode will be started If you want to stop ON TIMER Mode please press ENTER CANCEL again TO SET ON TIMER MODE This unit can be set to automatically turn on after a predetermined amount of hours up to 24 in the order of 0 5 1 1 5 2 2 5 3 4 5 6 8 10 12 16 20 24 AUTO 5 Place the remote controller so it is facing the unit When the des...

Page 11: ...MODE BY PRESSING MODE BUTTON Auto mode operation gives you the most comfort able airs by adjusting temperature humidity and fan speed automatically according to the room conditions 1 SELECT QUICK MODE BY PRESSING MODE BUTTON Quick mode operation allows you to make the room cool or warm quickly according to the room condi tions NOTES If it is necessary select fan speed or fan direction NOTES If it ...

Page 12: ...g temperature button COOL MODE MOTHOD BY USING MAIN CONTROL METHOD BY USING REMOTE CONTROLLER NOTES If it is necessary select fan speed or fan direction 1 SELECT COOL MODE BY PRESSING MODE BUTTON AUTO NOTES Fan speed changes as follows by pressing fan speed button on fan mode low middle high natural 1 SELECT FAN MODE BY PRESSING MODE BUTTON NOTES If it is necessary select fan speed or fan directio...

Page 13: ...ON NOTES If it is necessary select fan direction Fan speed control is not available because fan speed is set automatically on dehumidifier mode NOTES If it is necessary select fan speed or fan direction 1 SELECT HEAT MODE BY PRESSING MODE BUTTON Desired temperature is available from 18 C to 32 C To make room warm and comfortable adjust desired room temperature by using temperature button HEAT MODE...

Page 14: ...ng operation If you press economy button again the unit return to previous condition 1 Mild mode can be selected on auto mode quick mode cool mode fan mode dehumidifier mode heat mode Press turbo mild button to use mild mode while the unit turn on MILD MODE REMOTE CONTROLLER IS ONLY AVAILABLE Select by pressing TURBO MILD button 2 Mild mode is to reduce sound level of air from the fan and accordin...

Page 15: ... cleaner or soft brush 5 Dry the air filter completely in the shade after cleaing by neutral detergent 2 Remove upward the air filter 4 If the air filter is dirty clean that with water below 40 C melted neutral detergent 6 Insert the air filter into the insert grille in the right direction and then close the insert grille ...

Page 16: ...off the indoor unit and then unplug it from the wall Clean the air filters Cover the outdoor unit with the supplied cover this is very important to protect this unit BEFORE THE SEASON Make sure the air filters are clean Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions Make sure the unit is grounded Consult a serviceman for help PRECAUTIONS Do not use t...

Page 17: ...ely back on the compressor will delay for 3 minutes The air filter s is dirty or clogged Clean or replace filter s Unit is located near a heat When locating unit for the first time source heater stove etc make sure it is in a desirable location A door or window is open Shut door or window There is an obstacle in front of Remove obstacle intake or indoor unit The temperature has been set Check and ...

Page 18: ...n Heating Mode 2 800W 2 800W 2 800W Indoor Unit Dimensions 500x1830x350 WxHxD Outdoor Unit Dimensions 872x675x325 WxHxD Net Weight Indoor 40 Kg Outdoor 66 Kg Connection Type Flare the piping Gas 5 8 15 88mm Liquid 3 8 9 52mm Operating Indoor side Heating Mode min 21 C max32 C min 15 C max 27 C Condition Outdoor side Heating Mode min 21 C max43 C min 2 C max 24 C Design and specification are subjec...

Page 19: ...S N 3103908200 ...

Page 20: ...MODEL DPB 280L DPB 280LH OWNER S MANUAL FLOOR STANDING AIRCONDITIONER S1 ...

Reviews: