19
9. POWER ADJUSTMENTS
1. Vsus (SUSTAIN Voltage) : Discharge Sustain Voltage
. METER used : DIGITAL MULTIMETER (DC Voltage Measure Mode)
. Adjusting TP : TP204 (refer to PAGE 11)
. Adjusting VOLUME : RV203 (refer to PAGE 11)
. Standard Voltage : 170V (This value could be different from the optimum
adjusting voltage)
. Optimum adjusting Voltage : Stated in the LABEL
(See voltage adjustment label in the top of Panel Back Plate - PAGE 11)
2. Vadd (ADDRESS voltage) : DATA Input Voltage
. METER used : DIGITAL MULTIMETER (DC Voltage Measure Mode)
. Adjusting TP : TP206 (refer to PAGE 11)
. Adjusting VOLUME : RV204 (refer to PAGE 11)
. Standard Voltage : 60V (This value could be different from the optimum
adjusting voltage)
. Optimum adjusting Voltage : Stated in the LABEL
(See voltage adjustment label in the top of Panel Back Plate - PAGE 11)
*. As NEC Panel doesn't apply Vyer, it is unnecessary to adjust.