INSTALLATION

     Install the mobile ir conditioner in a flat and spacious location
     where the air outlets will not be covered up. A minimum 
     clearance of 30cm from a wall or other obstacles should 
     be kept. The appliance shall not be used in the laundry. 
     The plug shall accessible after appliance is positioned.
     Wiring shall be done according to National rules.
     

1   IMPORTANT:

2   DUCT MOUNT INSTRUCTIONS:

Exhaust Air Oulet

Duck

A)  TEMPORARY-

     1.  Attach one end of the duct to the exhaust air outlet of the 
          mobile air condition, first fit the left side of the duct on the
          exhaust air panel, then the right side duct. Push it 
          downwards, be sure to fix thoroughly. (See the figures)
     2.   Attach the other end of the duct to adaptor B.
     3.   Put the end of duct to a nearby window.

B) PERMANENT-

     1.  Attach one end of the duct to the exhaust air outlet of the 
          mobile air conditioner. According to the arrow direction, 
          first fit the left side of the duct on the exhaust air panel, 
          then the right side duct. Push it downwards, be sure to fix
          thoroughly. (See the figures)
      2. Install the adaptor A onto the wall by using 4 wall plug and
          screws, be sure to fix thoroughly. (See the figures)
      3. Attach the other end of the duct to adaptor A.
      4. Cover the hole using the adaptor cap when not in use.

The duct can be compressed or extended between 500mm 

and 2000mm, but it is desirable to keep the duct length to a 

minimum.

IMPORTANT:

     DO NOT OVER BEND THE DUCT (SEE FIGURE)

Adapter A

Rawlplugs

Skruer

max 120CM

min  30CM

Fig.8

Fig.9

Fig.10

30cm

30

cm

Fig.7

Summary of Contents for DOC-091R

Page 1: ...ORTABLE TYPE ROOM AIR CONDITIONER Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult your dealer for help or ELECTR ONICS Please keep this manual well W1 R C US LISTED UL and CUL listed ...

Page 2: ...TENTS 1 SAFETY RULES 2 NAMES OF PARTS 3 ACCESSORIES 4 OPERATION PANEL OF THE AIR CONDITIONER 5 OPERATING INSTRUCTION FOR THE AIR CONDITIONER 6 INSTALLATION 7 MAINTENANCE 8 TROUBLE SHOOTING 1 2 2 3 4 6 7 8 ...

Page 3: ...THESE DANGERS 4 ALWAYS STORE THE UNIT UPRIGHT IN ORDER TO MAINTAIN THE COMPRE SSOR IN A PROPER CONDITION 5 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 6 THE HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A SOCKET OUTLET 7 IF THE APPLIANCE IS COVERED THERE IS A RISK OF OVERHEAT 8 IF THE SUPPLY TOOL OF THIS APPLIANCE IS DAMAGED IT MUST BE REPLACED BY A REPAIR SHOP APPOINTED BY THE MANUFACTURER BECAUSE ...

Page 4: ...d please refer to the installation instructions for their usage ALKALINE BATTERIES 2 1 1 REMOTE CONTROLLER WATER PUMP DRAIN HOSE SCREWS 2 NAMES OF PARTS OPRATION PANEL AIR OUTLET REMOTE CONTROLLER CASTER REAR COVER FRONT COVER AIR INLET OUTDOOR WATER PUMP DRAIN HOSE POWER CORD AIR INLET INDOOR AIR OUTLET OUTDOOR AIR INLET OUTDOOR CONTINUOUS DRAIN HOSE FRONT VIEW SIDE VIEW REAR VIEW Fig 1 Fig 2 ...

Page 5: ...N Turn on off the unit MODES BUTTON Select the operation mode from COOL DRY FAN FAN SPEED BUTTON Press the button to select the fan speed from HIGH MED or LOW OPERATING PANEL TEMP SETTING BUTTON Press your desired room temperature setting by pressing the button up or button down DIGITAL DISPLAY TIMER ON OFF INDICATOR TIMER ON OFF BUTTON Program the on off timer function COOL DRY FAN HEAT INDICATIO...

Page 6: ...n off button to turn on the unit 1 BEFORE USE Dehumidifying and Cooling Operations O O O O The operating range for cooling operating is 17 C 30 C 63 F 86 F If the cooling or dehumidifying operations have been switched off and need switching on again in a short time allow approximately three minutes for the cooling or dehumidifying operations to resume Make sure the water pump drain hose is correct...

Page 7: ...omes on Press the FAN SPEED button to choose the fan speed Do not put the duct to window 6 TIMER OPERATION Setting the on timer Press the TIMER ON button when the air conditioner is off Select the time you need the unit start to operate The Operation Paned Window will display ON The starting time is adjustable from 0 00 to 24 Setting the off timer Press the TIMER OFF button when the air conditione...

Page 8: ...e the figures 2 Attach the other end of the duct to adaptor B 3 Put the end of duct to a nearby window B PERMANENT 1 Attach one end of the duct to the exhaust air outlet of the mobile air conditioner According to the arrow direction first fit the left side of the duct on the exhaust air panel then the right side duct Push it downwards be sure to fix thoroughly See the figures 2 Install the adaptor...

Page 9: ... the rubber blockage from the back drainage hole and drain the water off The unit will continue operating properly Drain Tank Safety Feature MAINTENANCE 1 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 2 DO NOT USE GASOLING THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT 3 DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE THE ELECTRICAL CAUE DANGER 4 IF THE POWER CORD IS DAMAGED IT SHOULD BE REPA...

Page 10: ...mperature is lower than the set temperature Cooling mode The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 NOT COOL ENOUGH Place the unit on a flat level ground if possible It is normal The ground is not level or not flat enough The sound comes from the ...

Page 11: ...ed This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sales of our electronic products Over the counter exchange for units that are initially defective Initial defective is described as when the dealer opens the unit and finds that it is inoperative or an individual customer openi...

Reviews: