7
Troubleshoo ng
Fault
Reason
Approach
1.no rota on
power on
1.motor no working
2.too low voltage
3.motor sha gets stuck
4.circuit board broken
1.push on high wind
2.turn to rated power
3.Strike motor shell to
make spindle smoothly or
repair it.
4.repair it(the same model
circuit board))
2.Apparent
vibra on
1.Rear guard loosens
2.Blade screw loosens
3.blade broken or imbalance
4.blade imbalance
1.Lock net hoop ghtly
2.screw fan blade ghtly
3.replace fan blade
4.turn over fan blade180
º
then install
3.Atomizer
working,
no mist
1.Water tank includes other
liquid(like aroma and
mosquito repellent)
2.water tank broken and full
of water
1.Clean water tank, mist
tank several mes.
2.put clean water in water
tank.
4.Atomizer no
working
1.The floater
1.Make floater float
5.Indicator light
off, no wind no
mist
1.Power plugs in not well
2.Power switch is off
1.Plug in well
2.switch it on
6.Indicator light
on, wind no mist.
1.water tank lacking water
2.Humidifier no working
1.put water in water tank
2.switch humidifier on
3.make floater pressure
plate ghtly
Summary of Contents for DMF-4010S