2

Remark per EMC Directive 89/336/EEC
To prevent flicker impressions during the start of the compressor (technical process) following installation conditions do apply.

1. The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of an low

impedance. Normally the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max!

2. No other equipment has to be connected to this power line.
3. For detailed installation acceptance please refer to your contract with the power supplier.

If restrictions do apply for products like washing machines, air conditioners or electrical ovens.

4. For power details of the air conditioner refer to the rating plate of the product.

ROOM AIR CONDITIONER INSTRUCTION

Remarques relatives à la Directive EMC 89/336/CEE
Pour eviter les phénormènes de scintillements(variation de lumière) et les parasites lors du démmarrage du compresseur, respecter
les consignes d’installation décrites dans le mode d’emploi.

1. Le raccordement au secteur doit être-fait à l’aide d’un cable de section suffisante pour eviter tout échauffement de celui-ci et les

chutes de tension (section recommandée 3x4mm

2

)

Cette ligne doit être protégée par un fusible ou disjoncteur de 16A

2. Aucun autre appareil ne doit être connecté sur cette ligne.
3. En cas de doute ou de difficulté contactez votre agence EDF. Vériflez qu’il nexiste pas de contraintes particulères pour l’instala-

tion et l’utilisation de ce climatiseur.

4. Pour les caractéristiques de l’appareil référez vous à sa plaque signalétique.

CONSIGINES D’INSTALLATION RACCORDEMENT ELECTRIQUE

Comentario de la Directiva 89/336 EEC de la EMC.
ára prevenir la sensación de golpeteo al arrancar el compresor(procesotécnico) debe aplicar las siguientes instrucciones de instalación

1. La conexión del aire acondicionado a la corriente eléctrica tiene que ser hecha a la distribución principal de energía. Esta distribución

tiene que ser de baja impedancia. Normalmente, la impedancia requerida se alcanza en el punto de fusión de 32A. El fusible del aire
acondicionado tiene que ser de 16A máximol.

2. Ningún otro equipo debe ser conectado a esta línea eléctrica.
3. Para normas detalladas de instalación por favor consulte el contrato con su suministador eléctrico, si tiene que aplicar restricciones

para productos como lavadoras, aire acondicionado u homos eléctricos.

4. Para detalles sobre las alimentación eléctrica del aire acondicionado consulte la placa de datos del aparato.

INSTRUCCIONES DE INSTALACION DEL AIRE ACONDICIONADO

Hinweis entsprechend EMV-Direktive 89/336/EEC
Um einen “Flicker-Effekt” beim Anlauf des Kompressors (kurzzeitiger Spannungseinbruch, technischer Vorgang) zu vermeiden, muß für fol-
gende installationsbedingungen gesorgt sein. (siche auch “Anweistingen zur installation.”)

1. Der Stromanschluß für die Klimpaanlage muß am Hauptverteller vorgenommen werden. Die Abzweigung muß mit niedriger Impedanz aus-

geführt werden. Normalerweise ist die erforderliche niedrlge impedanz bei einem Sicherungsanschlußpunkt von 32A erreicht.

2. An die gleíche Netzleitung dürfen keine anderen Geráte angeschlossen sein.
3. Seitens der lokaten Energieversorgungsuntemehmen bestehen möglicherweise Einschránkungen für Produkte wie Waschmaschinen,

Klimaanlagen, elektrische Öfen, etc. Für Einzelheiten zur Installation sehen Sie in Ihren Vertrag mit dem Energieversorgungsunternehmen.

4. Einzelheiten über die elektrischen Daten der Kimaanlage ersehen Sie auf dem Typenschild des Gerates.

ANWEISUNGEN ZUR INSTALLATION DER RAUM-KLIMAANLAGE

NOTA DELLA DIRETTIVA EMC 89/336 EEC
Allo scopo di prevenire l’ effetto di FLICKER (variazione della luce) alla partenza del compressore, durante l’installazione seguire l punti sot-
toelencatl.

1. Il collegamento dell’ alimentazione, del condizionatore, deve essere fatto con una linea preferenziale dlrettamente al quadro principale o

contatore, e deve essere a bassa impedenza.
Normalmente questa lmpedenza la si ottiene al punto di fusione di 32 A ; perll condizionatore usare un fusibile da 16 A max.

2. Nessun altro apparecchio elettrico dovra essere collegato alla stessa linea di alimentazione.
3. Per maggiori dettagll circa l’ accettazione dell’ installazione del condizionatore, fare riferimento al contratto con l’ Ente erogatore dell’

Energla Elettrica e verificare che non ci siano restrizioni in atto all’ Installazione di prodottl elettrici ad alto consumo.

4. Per le informazioni relative ai dati di allmentazlone del condizionatore, fare riferimento all’ etichetta posta sul prodotto.

INSTRUZIONI PER L’INSTALLAZIONE DEL CONDIZIONATORE 

D’ARIA PER STANZE

DMB-3003LH  2003.3.4 9:56 AM  페이지2

Summary of Contents for DMB-3003LH

Page 1: ...MODEL DMB 3003LH OWNER S MANUAL S1 DMB 3003LH 2003 3 4 9 57 AM 페이지20 ...

Page 2: ... for the outdoor unit this prevents water damage and vibration When installing in an area of high winds make sure to securely anchor the outdoor unit down with bolts and a metal frame When Connecting Refrigerant Tubing Keep all tubing as short as possible Use the flare method for connecting tubing Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting t...

Page 3: ... de instalación por favor consulte el contrato con su suministador eléctrico si tiene que aplicar restricciones para productos como lavadoras aire acondicionado u homos eléctricos 4 Para detalles sobre las alimentación eléctrica del aire acondicionado consulte la placa de datos del aparato INSTRUCCIONES DE INSTALACION DEL AIRE ACONDICIONADO Hinweis entsprechend EMV Direktive 89 336 EEC Um einen Fl...

Page 4: ...n 8 How to Install Batteries 9 Celsius to Fahrenheit Conversion Chart 9 To Set Auto Mode 10 To Set Quick Mode 10 To Set Cool Mode 10 To Set Only Fan Mode 11 To Set Dehumidifier Mode 11 To Set Heat Mode 12 To Select The Fan Direction 12 To Set On Timer Mode 13 To Set Off Timer Mode 13 To Set Sleep Mode 14 To Set Turbo Mild Mode 14 Emergency Operation 14 Installation Diagram 15 AC Connection Diagram...

Page 5: ...IGURATION 4 Indoor Unit A B1 B2 Cooling W 3220 Min 2560 Max 3370 Min 2560 Max 3370 Heating W 3500 Min 2490 Max 3520 Min 2490 Max 3520 B1 A B2 Capacity Unit A Unit B1 Unit B2 DMB 3003LH 2003 3 4 9 57 AM 페이지4 ...

Page 6: ...IT B1 A B2 OUTDOOR UNIT Service Cover Remove this cover to access the AC connection from this unit to the indoor unit Service Valve The indoor units and outdoor unit are connected by copper tubes which are connected here DMB 3003LH 2003 3 4 9 57 AM 페이지5 ...

Page 7: ...MR to operate by hand Open the front panel on emergency operating Remocon switch is usually used with remote con troller Indoor Unit Display Switch Panel Timer Yellow Lights on during the time of reservation mode Quick Red Lights on during the time of Quick Mode ON Red Lights on during the operation Air clean Green Lights on during the operation EMR REMOCON INDOOR UNIT DISPLAY DMB 3003LH 2003 3 4 ...

Page 8: ... to turn the unit on or off TEMPERATURE Buttons Press to raise or lower the desired temperature FAN SPEED Button Press to select the fan speed High Middle Low COVER Slide down to access most of the remote buttons Slide down further to access the battery compartment AUTO REMOTE CONTROLLER MODE Indicators Auto Quick Cool Fan Dehumidifier Heat Lights to indicate the mode selected TIMER Indicators Inc...

Page 9: ...RATION After the unit is fully connected and plugged in it can be turned on To turn the unit on and set it for remote operation follow the procedures below 1 Open the indoor unit s cover and make sure the EMER GENCY REMOTE switch is set to the REMOTE position this will allow the unit to operate with the remote controller 2 Press the ON OFF button on the remote controller to turn on the unit The On...

Page 10: ...old batteries with fresh ones 4 If the device is not to be used for a long period of time remove the batteries to prevent damage or injury from possible battery leakage 5 Do not try to recharge batteries not intended to be recharged they can overheat and rupture Follow battery manufac turer s directions HOW TO INSTALL BATTERIES To install the batteries follow the procedures below CAUTION IN CASE O...

Page 11: ...D will light on the indoor unit and ON will light in the re mote display 2 Press the MODE button until the Quick indicator appears in the display 3 The unit will then start cooling the room at the highest power AUTO 1 Press the ON OFF button on the remote control to turn the unit on the On LED will light on the indoor unit and ON will light in the remote display 2 Press the MODE button until the C...

Page 12: ...le through the speeds simulating a breeze NOTE If NATURAL is selected the NATURAL indicator on the indoor unit will light TO SET ONLY FAN MODE To operate only the fan so the unit will circulate the air proceed as follows TO SET DEHUMIDIFIER MODE Select this mode when there is high humidity To select follow the procedures below 1 Press the ON OFF button on the remote control to turn the unit on the...

Page 13: ...e fan speed press the FAN SPEED button until the desired speed appears in the display see below TO SET HEAT MODE To set the unit to heat the room to a desired temperature follow the procedures below NOTE When the heating orperation is started hot air delivery might be delayed due to warm up period 1 Press the ON OFF button on the remote control to turn the unit on the On LED will light on the indo...

Page 14: ...NOTE Press the ENTER button within 5 seconds of selecting the desired time If mote than 5 sec onds elapse steps 3 and 4 must be repeated 1 Press the ON OFF button of timer on the remote control to set the off timer mode HOUR and OFF on the re mote display will be displayed and TIMER will be flicked When you increase to press ON OFF you will get de sired time Then if pressing ENTER CANCEL button OF...

Page 15: ...erature and then increase that temperature throughout the night 1 Open the indoor unit s cover and make sure the EMERGENCY REMOTE switch is set to the EMER GENCY position 3 To turn the unit off slide or push the EMERGENCY REMOTE switch to the REMOTE position 2 The unit will then turn on and depending on the room temperature it will select the cool or heat fan speed and fan direction automatically ...

Page 16: ...ce man when replace the power cord set Drain Hose Ground Wire Not Supplied 3 8 side piping Signal Wire 1 4 side piping Drain Hose Wall Wall Cap Drain Hose Pipes Not Supplied Signal wire Copper Tubing At least 30cm 11 8in from unit 60 cm 23 6 inches c m 1 0 c m 3 9 inches 6 0 23 6 inches AC Outlet and Plug Plug into 220V 240V The added refrigerant according to the extention tube length 30g m Standa...

Page 17: ...N Y G Y G BRN BLU Y G BRN BLU Y G BRN Terminal Block Indoor Unit A L N N L Power NOTE We want you to observe bellow recommended specifications Part Name Power plug Power cable Circuit breaker Connection cable Recommended specifications 250V 16A Flexible H05RN F above 2 0mm2 20A H05RN F 0 5 or above x 3P x 8m AC CONNECTION DIAGRAM You should individually connect wires to terminals as bellow diagram...

Page 18: ...ers should be changed every 6 months If in a climate with cold winters once a year is adequate After getting rid of vinyl in the filter Deodorizing and Electrostatic use it CLEANING THE INDOOR COVER To clean the indoor cover follow the procedures below 1 Remove the left and right side to open the indoor cov er upward by two hands NOTE Please remove or insert the indoor cover by two hands 2 Pushing...

Page 19: ...it and then unplug it from the wall Clean the air filters Cover the outdoor unit with the supplied cover this is very important to protect this unit BEFORE THE SEASON Make sure the air filters are clean Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions Make sure the unit is grounded Consult a serviceman for help PRECAUTIONS Do not use this unit for anim...

Page 20: ...immediately back on the compressor will delay for 3 minutes The air filter s is dirty or clogged Clean or replace filter s Unit is located near a heat When locating unit for the first time source heater stove etc make sure it is in a desirable location A door or window is open Shut door or window There is an obstacle in front of Remove obstacle intake or indoor unit Thermostat is set too high Set ...

Reviews: