-18-
7. Trouble Shooting
* Facts you must know at trouble diagnosis or repairing
(1) The trouble diagnosis and repairing of set means Module .
In other words, find out which PCB modules are not working and replace them with normal
PCB modules.
(2) This TROUBLE SHOOTING list only contains representative and simple PCB trouble
diagnosis and Module Exchange method. Therefore, if you find Sets which are difficult to
diagnose or to repair, contact Daewoo Electronics.
(3) Basic TROUBLE SHOOTING procedure :
Check Trouble Symptoms
→
Detach Back Cover
→
Trouble Diagnosis
→
Replace broken
PCB module
→
Adjust white balance
→
Function Check
→
Repair Complete.
(4) Required equipments for trouble diagnosis
- Digital Multi-meter (measure Dc voltage, measure Diode Voltage, Short-Open test)
- Screwdriver (or electric screwdriver), plastic adjusting tool
(5) Before assemble/disassemble PCBs, check to see if AC Switch is OFF.
(6) After Back cover is closed, redo Heat-run for at least one hour by inputting Full white
pattern.
Symptoms of power, inverter, panel Trouble
<Symptom.1> Not even weak discharge (luminescence) shows on screen.
<Symptom.2> Discharge (luminescence) on screen is unstable
<Symptom.3> Set is producing unusual noise
Symptoms of VIDEO or JACK PCB Trouble
<Symptom.1> Only weak discharge (luminescence) shows on screen, but No Data is on
screen
<Symptom.2> Screen DATA is abnormal
<Symptom.3> Particular input signal (Video, etc.) does not operate
<Symptom.4> No SOUND
<Symptom.5> Remote Control or KEY does not operate
Summary of Contents for DLT-20W2
Page 1: ...Service Manual 20 LCD CHASSIS Model S M NO DSL140TEF0 SL 140T DLT 20W2 Jul 2007 ...
Page 4: ......
Page 8: ...4 Schematic Diagram 8 ...
Page 9: ... 9 Schematic Diagram ...
Page 10: ...Schematic Diagram 10 ...
Page 11: ...Schematic Diagram 11 ...
Page 12: ...Schematic Diagram 12 ...
Page 13: ...Schematic Diagram 13 ...
Page 14: ... 14 Schematic Diagram ...
Page 15: ... 15 Schematic Diagram ...
Page 16: ...6 PCB Data 16 TOP ...
Page 17: ...PCB Data 17 BOTTOM ...
Page 34: ... 34 11 Out Line DLT 20W2 ...
Page 35: ...12 Exploded View 35 DLT 20W2 ...
Page 36: ...SOFTWARE INSTALL UPGRADE ...
Page 41: ...SOFTWARE INSTALL UPGRADE 6 7 Please choose port LPT1 8 Please open HEX FILE ...