DLP-3022 SERVICE MANUAL
MODEL NAME
DOCUMENT NO
REVISION NO
REVISION DATE
PAGE
DLP-3022
ELT040605-001
00
04/06/05
33/73
(1) Signal Generator supply the pattern of above picture.
-
Timing
⇒
313
(Name : 1024
×
768 HF : 48.363 VF : 60.004 Resolution : 1024
×
768)
- Pattem
⇒
609
(Toshiba)
(2) After movement to 1.calibration on Factory Mode, move to sub menu as choice
of volume button.
(3) After movement to 1. PC Calibration, choose it with volume button.
(4)
If OK key, it starts the calibration automatically
How to exit the Factory Mode
S.MODE ==> P.MODE ==> PREV ==> OK
5) Adjustment verification
Adjustment as volume
“
0
”
and then 4 times of OK key
DESCRIPTION OF SPECIAL FUNCTIONS
1.
P.MODE (Picture Mode)