4-3. METHODS TO REPAIR
SYMPTOM
OF TROUBLE
CAUSE OF TROUBLE
REMEDY
Capillary tube is detached from
suction pipe
Replace suction pipe assembly
Overcooling
Defect of thermostat Replace
thermostat
Abuse voltage
Change to fit voltage
Do not appear frost on
Evaporator and leak refrigerant
from evaporator
Replace evaporator
Compressor sub and main coil’s
resistance value is unusual
Replace compressor
Defect relay
Replace relay assembly
Defect overload
Replace relay assembly
Bubble comes out when put
soapsuds on welding point
Reeled leak-pint
If cut between capillary tube and
dryer, refrigerant comes out
intermittently clogged certain part
in cooling cycle
Exchange clogged part
Door switch is not pressed
1.
Exchange door switch
pressing part or door assembly
2.
Adjust foot cause of cabinet
inclined
Defect motor F
Replace defect motor
Temperature-fuse is opened
Replace temperature-fuse
No cooling or
freezing
Defrost-heater is opened
Replace defrost-heater
Door is opened
Close door
Control switch position is MIN
Explain consumer how to use
control switch
( dial position is up to normal)
Do not appear frost on
evaporator and leak refrigerant
from evaporator
Replace evaporator
Compressor sub and main coil’s
resistance value is unusual
Replace compressor
Defect relay
Replace relay assembly
Weak cooling
Defect overload
Replace relay assembly
13
Summary of Contents for DIR-220
Page 1: ...Service Manual Refrigerator Model DIR 220 DAEWOO ELECTRONICS CO LTD S M No DIR2200010 DIR 300...
Page 4: ...2 EXTERNAL VIEWS 2 1 SIZE 1 DIR 220 3...
Page 5: ...2 DIR 300 4...
Page 16: ...5 DIAGRAM 5 1 WIRING DIAGRAM 1 DIR 220 2 DIR 300 15...
Page 17: ...5 2 PRATICAL WIRING DIAGRAM 1 DIR 220 16...
Page 18: ...2 DIR 300 17...
Page 19: ...5 3 AIR FLOW DIAGRAM 18...
Page 30: ...7 EXPLODED VIEW AND PART LIST 7 1 SET TOTAL EXPLODED VIEW 1 DIR 220 29...
Page 31: ...30...
Page 32: ...2 DIR 300 31...
Page 33: ...32...