background image

4

Operating Conditions:

This unit is designed to operate with a working environment between 13  and 35 .
If the unit has been switched off and needs to be switched on again quickly, allow approximately

three minutes for the correct operation to resume.

Do not connect the dehumidifier to a multiple socket outlet, which is also being used for other

electrical appliances.

Select a suitable location, making sure you have easy access to an electrical outlet.
Plug the unit into a 115V~  60Hz electrical socket-outlet with earth connection.
Make sure the Water Tank is correctly fitted otherwise the unit will not operate properly.

1. Plug the cord to the proper power requirement. The computer system of the unit will have a 
    self-check.  If it is normal, the POWER indicator flashes at 0.5Hz. Press ON/OFF button now,
    the unit will start  operating under DEHUMIDIFYING mode with 60% setting humidity. Press the
    HUMIDITY           or         button will change setting humidity. 
2. Press the CONTINUE button will go into continues dehumidifying mode, and this time the 
   HUMIDITY               and         button are disable.
3. Press the ON/OFF button to turn off the unit.(You do not meed to unplug the power cord except 
   when the unit will not be in use for a long period of time.)
 

OPERATING INSTRUCTIONS

Turning the unit 

ON

or

OFF

OPERATION

Water Tank

 

Water will drain into the tank. When the tank is full and the unit stops operating,

 the Water Full indicator light will flash. 

 Do not remove the water tank whilst the machine is still working or just stopping. 

 This might cause some water to drip. 

 To empty the water tank, remove the tank as shown, empty the water and replace 

 the tank back in the unit. Ensure components of water tank are correctly positioned.

 The machine will re-start when the water tank is restored in its correct position.

1. Drag out the bucket a little.

2. Hold the two sides of the 
    bucket with even strength,
   and pull it out from the unit.

3. Pour the water out.

Summary of Contents for DHC-250

Page 1: ...USE CARE MANUAL Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult your dealer for help or ELECTRONICS Please keep this manual well W1 R C US LISTED UL and CUL listed ...

Page 2: ...FUNCTIONS 1 SAFETY NOTES 1 NAMES OF PARTS 2 CONTROL PANEL 2 TECHNICAL SPECIFICATIONS 3 INSTALLATION 3 OPERATING INSTRUCTIONS 4 OPERATION 4 MAINTENANCE 5 TROUBLE SHOOTING 7 CONTENTS ...

Page 3: ...t to source of heat e g a radiator or heater tumble dryer etc II An area where oil or water is likely to splash III An area exposed to direct sunlight IV Near a bath shower or a swimming pool V In a greenhouse 5 Never insert your finger or other foreign objects into grills or openings Take special care to warn children of these dangers 6 Always store the unit upright in order to maintain the compr...

Page 4: ... POWER indicator At the first time to connect to the power it flashes slowly The POWER indicator lights when the unit is turned on and dark when the unit is turned off indicator Lights when the unit is on CONTINUOUS DEHUMIDIFYING mode WATER FULL indicator Lights when the bucket is full and the unit stops operating HUMIDITY Button When the unit is in operation the setting humidity will go up by pre...

Page 5: ...ICAL SPECIFICATIONS Capacity will vary according to actual room ambient temperature and humidity conditions INSTALLATION Install the mobile dehumidifier in a flat and spacious location where the air outlets will not be covered up Do not install underneath desks or inside cupboards as this will restrict the air flow Maintain a clearance of at least 20cm front and rear to maintain correct air flow o...

Page 6: ...de with 60 setting humidity Press the HUMIDITY or button will change setting humidity 2 Press the CONTINUE button will go into continues dehumidifying mode and this time the HUMIDITY and button are disable 3 Press the ON OFF button to turn off the unit You do not meed to unplug the power cord except when the unit will not be in use for a long period of time OPERATING INSTRUCTIONS Turning the unit ...

Page 7: ...t as this may damage the unit Do not wash the unit directly under a tap or hose The electrical components inside may be damaged and the unit become unsafe as a result Air filter Clean the air filter at least once every two weeks to prevent impaired performance of the unit Pull the water tankt out as shown Figure A and pull the Air Filter down as shown Figure B Removal Cleaning Wash the air filter ...

Page 8: ... water tank in the unit Replacement Unit enclosure Use a soft clean cloth to wipe the surface Do not use water as this may cause an electrical fault or shock hazard Water tank Wash the tank using warm water about 40 with neutral detergent Rinse and allow to dry Replace tank when dry ...

Page 9: ...plugged 3 Water tank not fitted correctly 4 Water tank is full 5 Defrosting 1 Blocked air filter 2 Room windows and doors open 3 Obstacles in air outlet or air inlet 1 Unstable setting of unit 2 Blocked filter Reposition unit Wash nylon filter Wash nylon filter Close room windows and doors Remove obstacles Switch power on Restore power cord Re position water tank Empty water tank After defrosting ...

Page 10: ...arranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sales of our electronic products Over the counter exchange for units that are initially defective Initial defective is described as when the dealer opens the unit and finds that it is inoperative or an individual customer opening a new ...