background image

INDEX

1. CHARACTERISTICS 

............................................................................................................................... 2

2. INSTALLATION 

........................................................................................................................................ 2

3. FUNCTION INSTRUCTION 

..................................................................................................................... 3

4. DEBUGGING AND OPERATION INSTRUCTION 

................................................................................... 4

5. COMMON OPERATION TROUBLE

 

........................................................................................................ 5

6.SUGGESTION

 

........................................................................................................................................... 5

7. WARNING

 

................................................................................................................................................ 5

8. TECHNICAL DATA 

.................................................................................................................................. 5

WARRANTY 

................................................................................................................................................. 6

1. CHARACTERISTICS

This digital controller starts and stops pump through MCU according to water flow and pressure. 
Completely replace the traditional pump control systems, which composed of pressure tank, pres-
sure switch, water shortage protection set, check valve etc. Compared with traditional electronic 
pressure control, this controller has the following obvious features and advantages.

Three modes:

Pressure mode

Pump motor through MCU Receive pressure data and flow singal to control pump start and stop.
And implement relative protection and failure display function

Time mode

Pump motor through MCU receive flow signal to control pump start and stop.
Start again according to set time, and implement relative protection and failure display function.

Flow mode

Pump motor through MCU receive flow signal to control pump start and stop.
And implement relative protection and failure display function.

2. INSTALLATION

3. FUNCTION INSTRUCTION

4. DEBUGGING AND OPERATION INSTRUCTION

    1.setting 

working 

mode

 

 

 

 

Press “ model” button, choose “pressure” “time” or “flow”, then

 

 

 

 

mode light on.Pressure mode is mainly used for no tower water

 

 

 

 

supply.The function is same as normal electronic pressure control,

 

 

 

 

you can set the starting pressure. The pressure gauge on the side

 

 

 

 

shows the system pressure . Starting pressure can be adjusted

 

 

 

 

on the head body of controller. Generally, it rotates 180 degrees,

 

 

 

 

and the starting pressure change 0.1bar. The adjustable range is

 

 

 

 

1.2-2.5bar, and the default is 1.5bar.This mode is factory setting.

    install 

see 

Diagram 

3

 

 

 

 

“Time” mode mainly used for mainly used for water replenishment

 

 

 

 

of water tower ,it avoids the user to start or stop the pump by

 

 

 

 

themselves frequently. The user can set up how long to start

 

 

 

 

again after filling up the water according to the amount of water

 

 

 

 

consumed each day. The set time can choose at 0.5h/6h/24h,

 

 

 

 

which means half an hour/6 hours/24 hours. When water is in

 

 

 

 

urgently need, it can reset by pressing the reset button to restart.

 

 

 

 

If the self-priming pump cannot discharge water in 12s, you can

 

 

 

 

long press the "Reset" , then pump will keep running.

    Install 

see 

Diagram 

4

 

 

 

 

3.“Flow” mode mainly used for water tower pressurization.

 

 

 

 

When the user's water consumption reaches a certain value,

 

 

 

 

the pump will be started and the pipeline will be pressurized.

 

 

 

 

The advantage is that when the water consumption of the

 

 

 

 

pipeline is lower, and it is no need to turn on the water pump,

 

 

 

 

avoiding suddenly start the pump at night , like the toilet

 

 

 

 

water supply at night. Install see Diagram 5

 

 

 

 

4.Under the pressure model, if the current pressure value less than 

 

 

 

 

the starting pressure value, and no water flow signal within 12S, it is

 

 

 

 

determined to be water shortage and appear relevant indicators.

 

 

 

 

The electric pump will run by itself for 10 seconds every 15 minutes, 

 

 

 

 

start normally working with water entering, If there is still without flow, 

 

 

 

 

no pressure, and then start shut down protection again. Then run 10s 

 

 

 

 

after another 15 minutes, and keep circulating. Pump will normally 

 

 

 

 

operate when detected water pressure.

    
 

 

 

 

5.Frequently start within 3 minutes (no flow signal within 3 minutes,    

 

 

 

 

pressure signal repeated ) more than 18 times, and the failure light 

 

 

 

 

means leakage protection. Leakage protection does not affect the 

 

 

 

 

pump’s normal operation, will not be forced pump shut down.

    
 

 

 

 

6.The pump can be restarted by pressing the "Reset"

    button 

at 

any 

time.

5. COMMON OPERATION TROUBLE

6.SUGGESTION

Try to suggest the clients to choose the suitable mode, operation instruction please refer the pic.

7. WARNING

1.The controller can't be used in the medical treatment or the system whichin the event of
failure will cause serious personal injury or property damage.In the maximum extent permitted
by low .the supplier and the agency will not he responsible for the damage which caused by
something in additionto the controller of any direct or indirect at any time.
2. The controller itself have no repair parts provide to the user , it must be maintenance e by
the relevant professionals and the control box can be,provided by standby application.
3. Cannecting the controller power and. pump must be. use the three core rouna caole. In order to 
Keep security,the earth wire must be connected in correct way!

The supplier and the agency should reserve all rights of controller instructions, including but not 
limited to the copyright interpretationand the right for further amend. When the instruction is modi-
fied forgive that it without prior notice.

8. TECHNICAL DATA

Rated Voltage: 220-240 V
Power: 1.1 kW
Working pressure: 10 bar
IP Degree: IP65
Max Ambient Temperature: 60°C
Rated current: 10(6) A

1

Summary of Contents for DAEPC-15

Page 1: ...Manufactured under license of Daewoo International Corporation Korea www daewoopowerproducts com USER S MANUAL DAEPC 15 Automatic pressure switch...

Page 2: ...INDEX 1 CHARACTERISTICS 2 2 INSTALLATION 2 3 FUNCTION INSTRUCTION 3 4 DEBUGGING AND OPERATION INSTRUCTION 4 5 COMMON OPERATION TROUBLE 5 6 SUGGESTION 5 7 WARNING 5 8 TECHNICAL DATA 5 WARRANTY 6 1...

Page 3: ...value of pump head Y L 8 M 20 23 30 Diagram 2 20 23 30 Diagram 1 1 Installation and maintenance the cotroller must be operated by professionals who proficient in this manual 2 This product only can b...

Page 4: ...ol three modes Pressure mode when pressure light on Time mode when time light on Flow mode when flow light on 1 Press it each time then the three mode lights are turned on in turn Can reset pump at an...

Page 5: ...pump will keep running Install see Diagram 4 3 Flow mode mainly used for water tower pressurization When the user s water consumption reaches a certain value the pump will be started and the pipeline...

Page 6: ...wire must be connected in correct way The supplier and the agency should reserve all rights of controller instructions including but not limited to the copyright interpretationand the right for furth...

Page 7: ...r more nodes teaser on the surfaces of the cylinder and the piston or destruction of piston rings Also the warranty does not cover failure of the automatic voltage regulator due to incorrect operation...

Page 8: ...www daewoopowerproducts com Manufactured under license of Daewoo International Corporation Korea...

Reviews: