21
1
RESET
: It is the water level to start drainage. The spin cycle starts 30 seconds after the reset level is reached. It is
the minimum water level to start operating the heater.
2
HEATER OFF
: . It is the minimum water level to start operating the heater. The heater starts running only when the water
level is above this measure.
3
WASH 1
: Water level for Baby Care program
4
WASH 2
: Water level for Normal, Delicate, Cold, Cotton 40, Cotton 60 or Night time program
5
WASH 3
: Water level for Normal, Delicate, Cotton 40, Cotton 60, Intensive, Intensive 40, Intensive 60 or Night
time program
6
LOCK OFF (Water level to unlock door)
: Water level to enable to open the door
7
LOCK ON (Water level to lock door)
: Water level to lock the door automatically due to the water in the tub.
8
Overflow Level
: Water level to start draining water due to overflow risk. The water supply is suspended and the water is
drained to lower the level to the reset level if the overflow level is reached.
3-1. Water Supply Level
1) Water Supply Level
3. Functional Structure