background image

 

10

 

 

IMPORTANT 

 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE 

12L Dehumidifier 

Model No. COL1471 

User Manual 

 

Using the Timer 

 

Press the 

Timer

 

Button

 (14) to enter the timer mode.  

 

The timer can be set in 1 hour increments, every press of the 

Timer Button

 (14) 

the set time will increase by 1 hour and the time will be displayed on the 

LED 

Display

 (15).  

 

The set time on the 

LED Display

 (15) will show as 

“07” for 7 hours

, etc. 

 

The 

Timer Indicator

 (22) above the 

Timer Button

 (14) will illuminate during the 

set time period. After the set time period has ended, the 

Timer Indicator

 (22) 

will go out. 

If the Timer is set with the unit on, the Timer will turn the Dehumidifier 

off

 at 

the end of the set time. 
If the Timer is set with the unit in standby mode, (i.e. with the Dehumidifier 

plugged in but not running), the Timer will turn the Dehumidifier 

on

 at the 

end of the set time. 

 

To cancel the timer, press the 

Timer Button

 (14) until the 

LED Display

 (15) 

returns to “00”. 

 

 

Humidity  

 

Press the 

Humidity Set Button

 (16) to check the current ambient humidity, 

press the button again to set the desired humidity.  

 

After setting the desired humidity level, the 

LED Display

 (15) will confirm the set 

value for about 3 seconds and then return to show the current ambient 
humidity. 

 

To view the current ambient temperature at any point, press and hold the 

Humidity Set Button

 (16) for 3 seconds. 

The range of target humidity is 30%, 35%, 40%, 45%, 50%, 55%, 60%, 65%, 70%, 
75% and 80%. 

In the “Continuous drying mode” the 

humidity cannot be changed. 

 
 

Colour Digital Display (3) 

The 

Colour Digital Display

 (3) will turn blue, green and red depending on the 

room humidity level in different ranges: 
 
Ambient humidity 

 45%, it turns blue. 

45% 

 ambient humidity < 65%, it turns green. 

Ambient humidity 

 65%, it turns red. 

 

 

 
 
 
 

Summary of Contents for COL1471

Page 1: ...1 12L Dehumidifier Model No COL1471 User Manual IMPORTANT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...ld liable for damages or injury incurred through improper or incorrect use Read and familiarise yourself with all operating instructions before using this Dehumidifier Before using your unit into the...

Page 3: ...ehumidifier within reach of children It is imperative to unplug from mains supply after the Dehumidifier has been used before it is cleaned and whilst being repaired Unplug after each use DO NOT opera...

Page 4: ...heat and or ignition such as radiators heaters other electronic equipment etc No naked flame sources such as lighted candles should be placed on the Dehumidifier The appliance must be installed and u...

Page 5: ...nything other than its intended use The Dehumidifier must always be stored and transported upright otherwise irreparable damage be caused to the compressor if in doubt wait at least 24 hours before re...

Page 6: ...this product This symbol identifies that the supply uses an alternating current mains supply You should now recycle your waste electrical goods and in doing so help the environment This symbol means w...

Page 7: ...ifier Remove all packing materials and discard responsibly Ensure all parts are present if applicable see Description of Parts below Description of Parts 6 9 8 1 2 3 4 5 7 10 1 Air Outlet 2 Control Pa...

Page 8: ...oducts that produce heat 2 In an area where oil or water may be splashed 3 Direct sunlight 4 Mechanical vibration or shock 5 Excessive dust 6 Lack of ventilation such as cabinet or bookcase 7 An uneve...

Page 9: ...sor will stop working the fan will stop working after a 30 second delay Both the fan speed and humidity can be adjusted whilst in Auto mode Continuous Drying Mode Press the Mode Button 17 until the Co...

Page 10: ...ugged in but not running the Timer will turn the Dehumidifier on at the end of the set time To cancel the timer press the Timer Button 14 until the LED Display 15 returns to 00 Humidity Press the Humi...

Page 11: ...ll buzz 5 times To clear the alarm When the buzz sounds press any button to stop the alarm The compressor and fan will shut down and all functions will pause until the Water Tank 8 has been emptied an...

Page 12: ...ghly before refitting to the unit Technical Specification Non Rewireable Mains Plug If your appliance is supplied with a non rewireable plug fitted to the mains lead and should the fuse needed replaci...

Page 13: ...priate plastics collection service Disposal of the Product You should now recycle your waste electrical goods and in doing so help the environment This symbol means waste electrical products at the en...

Page 14: ...ed Clean the air filter Is the intake duct or discharge duct obstructed Remove the obstruction from the discharge duct or intake duct No air intake Is the filter clogged Clean the air filter Noisy whe...

Page 15: ...se or any consumable parts The guarantee will berendered invalid if the product is re sold or has been damaged through inexpert repair The guarantee is only valid within the UK and Eire Your standard...