39
6-7. E4 - Water leakage during washing
1) Conditions of Occurrence
ῡ
In case water level falls below re-supply even after 15 times of re-supply prior to finishing of water
heating
2) All LEDs are turned off and 'E4' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-8. E9 - Abnormalities in water level sensor
1) Conditions of Occurrence
ῡ
In case water level frequency is of 15KHz or lower and 30KHz or higher during cycle due to
abnormalities in water level sensor, etc.
2) All LEDs are turned off and 'E9' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.