Adjustments
5
j
2. TAPE SECTION
Test Tape be used
HEAD ADJUSTMENT (AZIMUTH)
1. 10KHz test tape(example: MTT-114N) must be used for this adjustment.
2. Connect to VTVM or oscilloscope to the headphone jack or speaker terminal.
3. Press the play button.
4. Adjust the azimuth by using a screw driver to maintain the max. L&R output voltage.
5. Adjust tape A(1), tape B(2) respectively, Please secure the azimuth position by using locking paint.
RECORDING BIAS OSCILLATOR FREQUENCY ADJUSTMENT
1. Connect the frequency counter to TP603, GND.
2. Press the REC button.
3. Adjust L603 to obtain 80 KHz
±
500Hz
Tape
Contents
Use
MTT-111N
3 KHz
Tape Speed Adjustment
MTT-114N
10 KHz
Head Azimuth Adjustment
MTT-5511
Blank
Record Frequency Property
VTVM
Scope
R-CH
L-CH
47 kohm
47 kohm
Input Level
Measurement
Point
Input Point
Output Level
Measurement
Point
TAPE ALIGNMENT CHART
Step
Item
Reference Value
Test Tape
Adjust Point
Test Point
Note
FIG.
1
Tape Speed
Adjustment
Normal
3,015~3,025Hz
MTT-111N
RV601
Line Out L/R
Channel
Line Out L/R
Channel
Confirm Wow & Flut-
ter is within 0.35%
FIG.1
3,000~3,010Hz
MTT-111N
RV601
Line Out L/R
Channel
Confirm Tape Speed
of end position after
adjustment at tape
start position
FIG.1
High
5,820~6,180Hz
MTT-111N
- - - - - -
Confirm High speed
after normal speed
adjustment
FIG.1
2
Azimuth Adjustment
Maximum Level
Phase:Within90
∞
MTT-114N
Head Screw
Line Out L/R
Channel
FIG.2,3,4
3
Recording Bias Oscilla-
tor Frequency Adjust-
ment
80 KHz
±
0.5
MTT-5511
L603
TP603,GND
Adjust with frequency
counter connected.
FIG.1
FIG. 1 : Tape Speed & Record Bias Oscillator
Frequency Adjust Circuit
Test Tape : MTT-111N(3kHz)
MTT-5511(Blank)
Frequency Counter
Output Level
Measurement Point
Set
FIG. 2 : Tape Azimuth Adjust Location
(Record/Playback Head)
FIG. 3 : Tape Azimuth Adjust Head Screw & Waveform
FIG. 4 : Tape Azimuth Adjust Circuit & Waveform
Forward
Side
Reverse
Side
Adjust with Frequency
Counter Connected
L-CH
Peak
R-CH
Peak
Screw
Angle
Output Level
within
1 dB
within
1 dB
L-CH
Peak
R-CH
Peak
Screw Angle
V
H
Oscilloscope
L-CH
Output Level
Measurement Point
Set
Test Tape
MTT-114N
(10kHz)
Screen Pattern
In Phase 45 90 135 180
Good
Wrong
Summary of Contents for AXW-118
Page 1: ...AXW 118 AXW 128 AMI 926LW RW 9CD8301500 AXW 128 AMI 926LW RW AXW 118...
Page 3: ...Safety Precautions 2...
Page 4: ...Safety Precautions 3...
Page 5: ...Adjustments 4...
Page 7: ...Exploded View and Mechanical Parts List Model AXW 118 6...
Page 8: ...Exploded View and Mechanical Parts List Model AXW 118 7...
Page 9: ...AXL 122L 124L 125R 123DP 125DP 128L Exploded View and Mechanical Parts List Model AXW 128 8...
Page 11: ...Exploded View and Mechanical Parts List Model AMI 926LW RW 10...
Page 12: ...Exploded View and Mechanical Parts List Model AMI 926LW RW 11...
Page 13: ...Wiring Diagram 12 Model AXW 118 128 AMI 926LW RW...
Page 14: ...Block Diagram 13 Model AXW 118 128 AMI 926LW RW...
Page 15: ...Schematic Diagram 14 Model AXW 118 128 AMI 926LW RW Ass y Name MAIN...
Page 17: ...Schematic Diagram Model AXW 118 128 AMI 926LW RW Ass y Name TAPE 16...
Page 18: ...Schematic Diagram Model AXW 118 128 AMI 926LW RW Ass y Name CD 17...
Page 19: ...Schematic Diagram Model AXW 118 128 Ass y Name FRONT 18...
Page 20: ...Schematic Diagram Model AMI 926LW RW Ass y Name FRONT 19...
Page 21: ...Schematic Diagram 20 Model AXW 118 128 AMI 926LW RW Ass y Name POWER...
Page 22: ...P C B Pattern Layout 21 Model AXW 118 128 AMI 926LW RW Ass y Name MAIN PCB...
Page 24: ...P C B Pattern Layout 23 Model AXW 118 128 AMI 926LW RW Ass y Name CD PCB...
Page 25: ...P C B Pattern Layout 24 Model AXW 118 Ass y Name FRONT PCB...
Page 26: ...P C B Pattern Layout 25 Model AXW 128 Ass y Name FRONT PCB...
Page 27: ...P C B Pattern Layout 26 Model AMI 926LW RW Ass y Name FRONT PCB...