18
6. To remove high voltage capacitor.
(1) Remove a screw
¤
which secure the grounding ring
terminal of the H.V. diode
¤Ł
and the capacitor holder
¤Ø
.
(2) Remove the H.V. diode
¤Ł
from the capacitor holder
¤Ø
.
(3) Reverse the above steps for reassembly.
High voltage circuit wiring
7. To remove magnetron.
(1) Remove three screws
¤
which secure the
magnetron
¤Ł
.
(2) Remove the magnetron
¤Ł
.
(3) Reverse the above steps for reassembly.
1
3
2
2
1
MAGNETRON
H.V. CAPACITOR
H.V.
DIODE
H.V. TRANSFORMER