23
TROUBLE SHOOTING GUIDE
(TROUBLE 3)
No microwave oscillation even though fan motor rotates.
CONDITION
CHECK
RESULT
No
Continuity
Continuity
Continuity in
backward
direction
Continuity
0 or
¡
Ä
Ω
No
Continuity
No
Continuity
0 V
Approx
12 VDC
CAUSE
Defective
high voltage
transformer
Defective
high voltage
rectifier
Defective
magnetron
Defective
magnetron
Defective
high voltage
transformer
Defective
high voltage
transformer
Defective
touch control
circuit
Faulty
contacts of
RELAY
(RY1) or open
relay coil
REMEDY
Replace
Replace
Replace
Replace
Replace
Replace
Replace
Replace
No microwave
oscillation
Check continuity of high
voltage fuse
Check continuity of high
voltage rectifier in
forward and backward
direction with DC
megger
Check continuity of high
voltage capacitor
terminals with wires
removed
Connect megger leads to
magnetron terminal and
magnetron body
Check resistance of
primary and secondary
coil of high voltage
transformer
Check continuity of
magnetron with wires
removed
Check continuity of
filament terminal of high
voltage transformer
Check D.C. voltage
being supplied to
RELAY (RY1) coil
Replace high voltage fuse
Summary of Contents for KOC-995T0S
Page 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION...
Page 9: ...8 CONTROL PANEL 1 KOC 995T0S...
Page 10: ...9 CONTROL PANEL 2 KOC 995T0S11...
Page 32: ...31 WIRING DIAGRAM...
Page 33: ...32 SCHEMATIC DIAGRAM...
Page 34: ...33 SCHEMATIC DIAGRAM...
Page 35: ...34 SCHEMATIC DIAGRAM...
Page 36: ...35 EXPLODED VIEW AND PARTS LIST 1 KOC 995T0S 1 EXPLODED VIEW...
Page 39: ...38 EXPLODED VIEW AND PARTS LIST 2 KOC 995T0S11 1 EXPLODED VIEW...
Page 47: ...46 P C B CIRCUIT DIAGRAM 1 PCB CIRCUIT DIAGRAM...