38
6. Case of no stopping of the count down timer
When the door is opened during operation, the count down timer does not stop.
(KOC-922T9S/R)
(KOC-923T9S/R)
POINT
STATE
DOOR OPEN
DOOR CLOSED
A
OPEN
CLOSE
B
+5V DC
GND
CN1
1
2
C5
+5V
R1
C4
3
R2
A
B
D.O.M SW
CN1
2
1
D6
+5V
R3
C1
15
R4
A
B
D.O.M SW
CHECK NO
METHOD
REMEDY
Check the stage(ON,OFF) of the door open
1
monitor switch by resistance
Replace door open monitor swith.
measurement.