20
1. How to start
1) Press “FRZ.TEMP” button 5 times while pressing
“REF.TEMP” button at the same time.
2. How to stop
1) Push “FRZ.TEMP” button 1 time.
2) It stops automatically in 4 minutes from the start.
3. All the error codes are reset if they turn to be normal.
4. Error display
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
Temperature Control Buttons
Lamp LED of Inner control
(Full down mode and forced defrost mode are displayed while pressing
“REF.TEMP” button at the error display mode)
REF. LED “1” is on and off (twice)
Forced defrost mode for A/S
REF. LED “1” is on
Full Down mode
REF. LED “1” is on and off
EEPROM : defective
REF. LED “2” is on and off
Return after defrosting : defective
REF. LED “3” is on and off
Cycle : defective
REF. LED “5” is on and off
F-Door Switch : defective
FRZ. LED “1” is on and off
R-Door Switch : defective
FRZ. LED “2” is on and off
D-sensor : open (“Lo”), short (“Hi”)
FRZ. LED “3” is on and off
RT-sensor : open (“Lo”), short (“Hi”)
FRZ. LED “4” is on and off
R-sensor : open (“Lo”), short (“Hi”)
FRZ. LED “5” is on and off
F-sensor : open (“Lo”), short (“Hi”)
Display
CONTENTS
4-9. Error Display
4-9-1. FRS(N)-U20IC Type
”1”
LED No
→
”2”
”3”
”4”
”5”
Summary of Contents for FRN-U20IC
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 33: ...32 5 WIRING DIAGRAM 5 1 FRS U20IC R 134a R C Type...
Page 34: ...33 5 2 FRN U20IC R 600a R C Type...
Page 35: ...34 5 3 FRS U20BC R 134a R C Type...
Page 36: ...35 5 4 FRN U20BC R 600a R C Type...
Page 37: ...36 5 5 FRS N U20D E F G R 600a or R 134a R C Type...
Page 68: ...67 8 5 Dispenser Water Flow...