DAEWOO ELECTRONICS FR-630NT Service Manual Download Page 9

8

SPECIFICATIONS

3. POWER CORD

NO

SHAPE OF POWER CORD

PART CODE

DESCRIPTION

REMARK

1

3011315000

CP-2PIN

For european country

2

401RA17200

CP-2PIN

For other country

3

4006D17101

KP-30

For America & El Salvador

4

401PD17101

KP-211

For Japan & Taiwan

5

3011300801

BP-3PIN

6

3011303010

# 267

For Chile

7

3011315310

For Israel

8

3011303050

BS-1363A

For U.K, Middle Asia Singapore & Malaysia

9

3011301200

KP-551/550

For China & Australia

*

Upper power cord’s part code is only for lead wire, without any kinds of terminal or housing

 

Summary of Contents for FR-630NT

Page 1: ...Service Manual Refrigerator Model FR 630NT NB FR 662NT NB FR 700NT NB http svc dwe co kr Nov 1999 DAEWOO ELECTRONICS CO LTD S M No FR630NT010...

Page 2: ...e leakage of electricity 2 You could handle a part in the vicinity of electricity after unplugging 3 You should put on rubber gloves to prevent an electric shock on operation test 4 Make sure the rate...

Page 3: ...partment Lamp Shelf Ffreezer Case Icing Guide Icing Ice Box Refrigerator Compartment Lamp Cover Cubic Duct Fresh Case Shelf Refrigerator Deodorant Cover Vegetable Case Vegetable B Case Vegetable A Gui...

Page 4: ...orator Forced Defrosting System DEFORST CONTROL Automatic Start Stop NET WEIGHT 85 kg 92 kg 95 kg REFRIGERANT R12 VOLTAGE V HZ 100 50 60 110 60 115 120 60 127 60 220 50 220 60 230 50 240 50 COMP MODEL...

Page 5: ...TYPE NAME X 783NHBZZ 52 X 317NHBYF52 197NHBYY 52 X 197NHBYY 52 197NHBYY 52 PART CODE X 3018119390 X 3018119950 3018119920 X 3018119920 3018119920 PTC RESIS TANCE X S220 X S068 S330 X S330 S330 PART C...

Page 6: ...T CODE 3015905300 3015905300 3015905300 3015905300 3015905300 3015905300 3015905300 3015905300 REVOLUTION 2200RPM 2200RPM 2200RPM 2200RPM 2200RPM 2200RPM 2200RPM 2200RPM REFRIGERANT R12 R134a VOLTAGE...

Page 7: ...CODE 3013600010 3013600010 3013600010 3013600010 3013600080 3013600080 3013600080 3016800080 REFRIGERANT R12 R134a VOLTAGE V HZ 100 50 60 110 60 115 120 60 127 60 220 50 220 60 230 60 240 50 TYPE NAME...

Page 8: ...60 110 60 115 120 60 127 60 220 50 220 60 230 60 240 50 OPERATING TEMPERATURE X 77 PART CODE X 3017200500 REFRIGERANT R12 R134a VOLTAGE V HZ 100 50 60 110 60 115 120 60 127 60 220 50 220 60 230 60 24...

Page 9: ...ountry 3 4006D17101 KP 30 For America El Salvador 4 401PD17101 KP 211 For Japan Taiwan 5 3011300801 BP 3PIN 6 3011303010 267 For Chile 7 3011315310 For Israel 8 3011303050 BS 1363A For U K Middle Asia...

Page 10: ...rmal PCM High glossy Bright PCM Dull laminasheet High glossy Laminasheet Normal PCM High glossy Bright PCM PARTCODE X 3010081960 X X X 3010077430 X X Refrigerant R12 R134a COLORTYPE Dull laminasheet H...

Page 11: ...imes then only Q F LED red is lit 3 REF SET Button 1 Temperature Regulation of Freshfood Compartment 2 Middle right Icons are lit by pressing the button 3 When Q R Mode is set Refrigerator Mode s Icon...

Page 12: ...erature regulation by REF SET Button 2 R Fan is controlled by On Off point of each mode 3 ON OFF DIFF 0 35 Middle 1 Off point 1 0 4 3 1 DIFF 2 5 Prevention of Weak refrigeration 1 When weak refrigerat...

Page 13: ...Defrosting Pause Fan delay SILENT starts if conditions to happen 3 Once SILENT starts all the electric devices COMP F Fan R Fan turn Off and only SILENT Icon is lit 4 Terms to finish SILENT Mode F Se...

Page 14: ...than 60 hours under the condition that terms of 1 and or 2 are not satisfied 6 Defrostiong Mode 1 COMP 2 F FAN 3 R FAN 4 HEATER 1 Defrosting Period 1 Time 50minutes 2 COMP and F Fan are On R fan is in...

Page 15: ...rence RT Sensor disconnection short circuit Control deletion of control condition by RT Sensor Dissolution if RT Sensor is in normal state it is finished by itself Limit time 4min Check error with out...

Page 16: ...cool mode at defrosting mode Dissolution the end of defrosting is done by D Sensor 8 Forced Defrosting 1 Defrosting Mode A S Heater Forced Defrosting 1 Start press REF SET Button 5 times while pressi...

Page 17: ...t Door 5 times while pressing FRZ SET Button 2 Control 1 Electric devices turn Off except for F Fan and R Fan 2 Fan Control 3 Dissolution 1 Open and close Refrigerator Freshfood Compartment Door 5 tim...

Page 18: ...17 DIAGRAM 3 CIRCUIT DIAGRAM...

Page 19: ...y Chilled room It is good for the storage of fishes and meats Crisper It is suitable to store vegeta ble and fruit The moisture panel which is attached to the cover humidity properly Vegetable and fru...

Page 20: ...19 DIAGRAM 3 REFRIGE RANT CYCLE DIAGRAM C O M P R E S S O R W I C O N H O T P I P E D R Y E R C A P I L L A R Y T U B E E V A P O R A T O R A C C U M U L A T O R S U C P I P E P I P E C O N S...

Page 21: ...Cover and Cabinet surface to remove the Cover Be careful not to break the hooks of Cover and not to damage the Cabinet surface 2 Remove 4 bolts with 10mm wrench 3 Disconnect Connector Housing 4 Lift F...

Page 22: ...dle Decorator from up to down Be careful not to damage the surface of Handle and door Once it is peeled or damaged corrosion may occur from metal parts beneath the handle 3 Remove the 2 Handle screws...

Page 23: ...kwise Lamp 15W 3 Pull Light bulb Base down forward with snap if necessary In assembling push it upward with snap Be careful not to damage the Liner surface 4 1 F LOUVER A 1 Remove 4 caps on the louver...

Page 24: ...Push fingers into the 2 holes to pull out 5 Pull the top of louver forward slowly while lifting the bottom Be careful not to damage the insulator behind louver 4 2 F LLOUVER B 1 Pull the louver forwa...

Page 25: ...shrinkage tube to each wire 2 Connect new sensor wires and old ones and put soldering on the connecting part 3 Move shrinkage tubes to hide the connecting part and give mild heat around them to shrink...

Page 26: ...the Motor F and R Fan Motor are distinguished by their wire colors so be careful not to change the motors Blue Wire for R Fan Motor Red Wire for F Fan Motor See to it that wire out direction is corre...

Page 27: ...ing on the connecting part 1 Move shrinkage tubes to hide the connecting part and give mild heat around them to shrink 8 Exchange of Temperature Fuse 1 Remove fuse fixing clip down left of evaporator...

Page 28: ...tment floor to protect it 2 Remove 2 screws left right of evaporator 3 Cut black gum out 4 Pull pipes about 50mm forward 5 Disconnect pipes by unsoldering them 10 Exchange of Defrost Heater 1 Remove c...

Page 29: ...ire on the top right 2 Remove defrosting sensor on the top right of evaporator 3 Pull evaporator forward slowly until defrosting heater appears Be careful not to damage suction pipe and capillary pipe...

Page 30: ...ove left rubber cap first then right one White wire is for the left rubber while gray wire is for the right one 11 1 R Light Bulb R LAMP 1 Hold light bulb cover to pull it down 2 Turn light bulb count...

Page 31: ...to pull it down 2 Turn light bulb counterclockwise to pull it out Be careful not to break hooks while removing the cover 3 Remove left Lamp Socket and right R Sensor Housing by pulling them out smoot...

Page 32: ...careful not to break hook 15 Side Louver 1 Remove all the parts of fresh food dompartment excet for cubic duct and return cap 2 Pull out sensor connector of left louver 3 Remove screw on the top of l...

Page 33: ...sert screw driver into the gap to pull out 2 Pull it out 17 R Sensor 1 Cut out only sealing sponge on the insulator in straight way along the insulator 2 Separate the Insulator form Louver by pressing...

Page 34: ...ntrol Panel 1 Place any sheet right of panel to protect surface of it 2 nsert small screw driver into the gap to lift panel window up 3 Insert another driver into the gap and move it left loosen 2 hoo...

Page 35: ...Cover screws 2 Pull the cover up to remove 3 Remove P Relay Band by pressing it up toward the Compressor 4 Remove Relay Assembly from Compressor 5 Cut out Service Pipe and tiny pipe of Dryer 6 Remove...

Page 36: ...s using soldering torch 3 Cut out Dryer fixing cable 4 Turn the Drain Hose by 90degrees to remove 5 Press the Housing Locker down to remove it 6 Pull out Wire condenser Be careful not to damage pipes...

Page 37: ...9 Remove Bell mouth by pulling them aside 10 Press the Motor Band down to remove it 11 Lift the Motor up to remove 21 Return Duct Cover 1 Insert screw driver into the gap to pull out Be careful not t...

Page 38: ...37 EXPLODED VIEW AND PARTS LIST 1 EXPLODED VIEW FR 630NT NB FR 662NT NB FR 700NT NB...

Page 39: ...STARTING 1 REFER TO 4 8 TRANS POWER 1 REFER TO 6 9 3010519200 BOX M PCB PP 1 10 PCB MAIN AS N808 1 REFER TO 6 11 HARNESS RUN CONN 1 12 3012905501 HINGE M T3 2 PO 1 13 3014901820 SHAFT M HI S20C 1 14 3...

Page 40: ...A PP 2 50 MOTOR R DC MOTOR 1 REFER TO 5 51 MOTOR F DC MOTOR 1 REFER TO 5 52 3018908000 LOUVER F B FRB 5070NB 1 53 3014524800 PLATE SENS 1 54 3011800400 FAN ABS 2 54 3018904201 LOUVER F B PP 1 55 3013...

Page 41: ...79 3014700200 ROLLER V CASE R L 2 2 4 80 3015303300 SUPPORTER ROLL R L 2 2 4 81 3017815000 SHELF R U AS FRB 5070NB GALSS 1 3017813100 SHELF R U AS FRB 5270NB GALSS 1 3017813000 SHELF R U AS FRB 5570NB...

Page 42: ...R DR AS PVC S 1 109 3019007300 POCKET F U GPPS 1 110 3019003500 POCKET F T GPPS 1 111 3012307520 GASKET F DR AS PVC S 1 112 ASSY F DR FRB 5070NT NB 1 REFER TO 20 113 ASSY R DR FRB 5070NT NB 1 REFER T...

Page 43: ...5 PIPE CONN A 3 CORD POWER AS 16 PIPE SUC CONN 4 SCREW MACHINE 17 PIPE SUCTION AS 5 ABSORBER COMP 18 BAND RELAY 6 COMPRESSOR 19 SWITCH P RELAY AS 7 ABSORBER COMP AS 20 FIXTURE C FAN 8 WASHER SPECIAL 2...

Page 44: ...ELECTRONICS CO LTD 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC E mail G7F00E web dwe co kr FAX 032 510 7630 TEL 032 510 7622 PRINTED DATE SEP...

Reviews: