14
CIRCUIT OPERATION
SERIES INPUT
When the series recording proceeds after setting the series recording to “on”, this port is used to receive
the control signal to the set which will be recorded continuously after pre-recording set.
WARNING OUTPUT
This port is used to inform emergency status of Time Lapse VCR Set to outsider.
0V
200ms
5V
0V
EMERGENCY
status term
500ms
HIGH
LOW
5V
0V
5V