![DAEWOO ELECTRONICS DSA-240L-R Service Manual Download Page 44](http://html1.mh-extra.com/html/daewoo-electronics/dsa-240l-r/dsa-240l-r_service-manual_499341044.webp)
42
DESCRIPTION
Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect
Power ON and Voltage less than 4.25V, and then send Reset Signal.
Reset(8)
R13
5.6K
1K
R12
18
CC9
CE4
4.7uF/50V
IC5
7042P
10.3
MICOM
4.25V
H
L
t
t
POWER
ON
Vcc (+5V)
DELAY TIME
FOR POWER ON
RESET