background image

6

Installation Specifications

Cutout Dimensions

Stiffener

Cabinet face

Countertop

Floor

3/8” min. (1.0 cm) space 

behind raised vent 

chassis to clear stiffener

3/8” min. (1.0 cm)

flat countertop overhang

required behind cutout

ERV or PRV series raised 

vent: Check raised vent 

dimensions/specifications 

to determine proper fit

 SGM series cooktop

Stiffener

Cabinet face

Countertop

Floor

5/8” min. (1.6 cm) space 

behind raised vent 

chassis to clear stiffener

4 5/8” (11.7 cm)

9 7/8” (25.1 cm) with 

CABP3 blower installed

5/8” min. (1.6 cm)

flat countertop overhang

required behind cutout

RV series raised vent: 

Check raised vent 

dimensions/specifications 

to determine proper fit

 SGM series cooktop

Side View - SGM Series Cooktop with  

ERV or PRV Series Raised Vent

Side View - SGM Series Cooktop with  

RV Series Raised Vent

All tole1/16” (+1.6 mm), -0, unless otherwise noted.

IMPORTANT:

 Be careful to use the correct cutout diagram (on the facing page) to determine the countertop dimensions 

for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cut-

ting the countertop.

Countertop Dimensions

Installation Type

Cutout 

Diagram

C Min.

D

E

F

G

H

SGM304 without raised 

vent

Figure 1 

(Square)

2 7/8”

(7.3 cm)

19 3/4”

(50.2 cm)

27 3/4”

(68.6 cm)

NA

NA

NA

SGM304 with ERV30, 

ERV3015 and PRV30

Figure 1 

(Square)

3/8”

(1.0 cm)

22 1/2”

(57.2 cm)*

27 3/4”

(68.6 cm)

NA

NA

NA

SGM304 with RV30

Figure 1 

(Square)

5/8”

(1.6 cm)

22 1/4” 

56.5 cm)*

27 3/4”

(68.6 cm)

NA

NA

NA

SGM365 without raised 

vent

Figure 1 

(Square)

2 3/8”

(6.0 cm)

19 3/4”

(50.2 cm)

33 5/8”

(85.4 cm)

NA

NA

NA

SGM365 with ERV36, 

ERV3615 and PRV36

Figure 1 

(Square)

3/8”

(1.0 cm)

22 1/2”

(57.2 cm)*

33 5/8”

(85.4 cm)

NA

NA

NA

SGM365 with RV36 

Figure 1 

(Square)

5/8”

(1.6 cm)

22 1/4”

(56.5 cm)*

33 5/8”

(85.4 cm)

NA

NA

NA

SGM466 without raised 

vent

Figure 1 

(Square)

2 7/8”

(7.3 cm)

19 3/4”

(50.2 cm)

44 3/4”

(113.7 cm)

NA

NA

NA

SGM466 with PRV46

Figure 2 

(Notched)

3/8”

(1.0 cm)

22 1/2”

(57.2 cm)*

44 3/4”

(113.7 cm)

43 1/2”

(110.5 cm)

5/8”

(1.6 cm)

2 5/8” **

(6.7 cm)

SGM466 with RV46

Figure 2 

(Notched)

5/8”

(1.6 cm)

22 1/4”

(56.5 cm)*

44 3/4”

(113.7 cm)

43 1/2”

(110.5 cm)

5/8”

(1.6 cm)

2 3/8” **

(6.0 cm)

* Total cutout depth, accommodates both the cooktop and raised vent 

** 

IMPORTANT:

 Notch depth is included in total cutout depth 

(D)

DO NOT

 add notch depth to total cutout depth 

(D)

.

Summary of Contents for SGM466BLP

Page 1: ...Installation Instructions Models SGM304 SGM365 SGM466 Gas Cooktop Part No 65141 Rev M...

Page 2: ...instructions for future reference and the local electrical inspector s use NOTE Dacor is not responsible for service required to correct a faulty installation 2007 Dacor all rights reserved If You Nee...

Page 3: ...ORTANT If you smell gas Do not use or light any appliance Do not touch any electrical switch or use any electri cal devices including the telephone in your building From a neighbor s phone immediately...

Page 4: ...p Do not climb on any part of the appliance WARNING General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety precau ti...

Page 5: ...s 19 1 2 49 5 cm 21 53 3 cm 4 10 2 cm chassis height 36 91 4 cm 33 1 2 85 1 cm including embosses in side of chassis 19 1 2 49 5 cm 21 53 3 cm 1 5 8 4 1 cm bottom of base to cooking surface 4 10 2 cm...

Page 6: ...Chassis Bottom Diagram for label location Units equipped for high altitude operation have an H at the end of the model number listed on the product data label Check your local building codes for the p...

Page 7: ...et below allow for the routing of gas and electrical service behind it The installation must allow for the following Access to the gas shut off valve and regulator when the unit is installed Access to...

Page 8: ...ions against the table below and the correct diagram before cut ting the countertop Countertop Dimensions Installation Type Cutout Diagram C Min D E F G H SGM304 without raised vent Figure 1 Square 2...

Page 9: ...tible surface Rear wall 1 7 8 min 4 8 cm E C D H H G F 7 1 2 19 1 cm min to combustible side wall above countertop both sides Vertical combustible surface Rear wall 1 7 8 min 4 8 cm 4 1 4 10 8 cm min...

Page 10: ...as flow towards the cooktop Do not apply excessive pressure when tightening gas connections and fittings Do not use Teflon tape or plumber s putty on flexible gas line connections Test the gas lines f...

Page 11: ...e proceeding The cooktop must be properly grounded at all times when electrical power is applied Prior to operating the cooktop read the accompanying use and care manual carefully 1 Make sure all the...

Page 12: ...l See inside cover for location Dacor is not responsible for the cost of correcting problems caused by a faulty installation Normal Flame Appearance Installation Checklist warning To ensure a safe and...

Page 13: ...left rear right front 86408 Burner cap right rear 86523BM Burner ring right rear 86407 SGM365 Description Dacor Part Number Regulator 82540 Grate large 82925SB Grate small 62443SB Burner cap left fron...

Page 14: ...12 Wiring Diagrams...

Page 15: ...13 Wiring Diagrams...

Page 16: ...14 Wiring Diagrams...

Page 17: ...15 Notes...

Page 18: ...16 Notes...

Page 19: ......

Page 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: