PLANNING

GUIDE

www.Dacor.com      Phone: (800) 793-0093  

Specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

8.12

RV30, RV36, RV46

fRoNt ExhAUst DImENsIoNs

cABP3 BLoWER - Bottom ExhAUst

ExhAUst LocAtIoNs AND DImENsIoNs

foR IN-LINE/REmotE BLoWER coNfIGURAtIoNs

(ILhsf oR REmP sERIEs BLoWERs)

fRoNt ExhAUst DImENsIoNs

cABP3 BLoWER - RIGht ExhAUst

fRoNt ExhAUst DImENsIoNs

cABP3 BLoWER - LEft ExhAUst

ExhAUst LocAtIoNs AND sIDE DImENsIoNs

foR cABP3 INtERNAL cABINEt BLoWER

 

 Side Exhaust Locations (3 1/4” X 10”)

 

 

 

 

 Vertical center line of bottom exhaust lines up with vertical 

      

 

center line of chassis 

 

 

 

 Internal cabinet blower mounting location 

 Bottom Exhaust Location (3 1/4” X 10”)

 

 

CL

CL

CL

1 7/8" *

(48 mm)

1 7/8" * (48 mm)

Front View

Bottom View

14 3/8"

(365 mm)

 

 

 

*Back of unit lines   

 up with back of 

 cutout

RV

8 3/8" (213 mm)

from back of RV

cutout to center line

of CABP3 exhaust

in any orientation

(bottom, or side 

exahust)

Bottom exhaust

configutation

with rear or bottom

duct routing

DUCT

DUCT

CL

CABP3

Cooktop

Duct connection

center line

B

Raised vent

center line

Countertop

3 1/4 X 10

Duct

connection

11 5/8"

(295 mm)

Duct connection

center line

C

Raised vent

center line

Countertop

3 1/4 X 10

Duct

connection

11 3/4"

(298 mm)

25 5/8"

(651 mm)

Duct connection

center line

A

Raised vent

center line

Countertop

3 1/4 X 10

 Duct connection

Planning the Duct Work (continued)

Model

A

B

C

RV30

RV36

2” (51 mm)

6” (152 mm)

12” (205 mm)

RV46

5” (127 mm)

9” (229 mm)

9” (229 mm)

Document # PG08-003

Revised 03/29/10   Page 6/7

30”, 36”, 46” Wide,

Raised Vent

Summary of Contents for RV30

Page 1: ...3 8 848 mm RV46 46 1168 mm 43 3 8 1102 mm All tolerances 1 16 0 1 6 mm 0 unless otherwise stated NOTES Install these raised vents only with approved Dacor 1 cooktops See the planning guide for the pa...

Page 2: ...conduit parallel to the duct work and connect it to the remote blower and raised vent on the ends There are two 7 8 access holes in the bottom of the raised vent for connecting the wiring to the blowe...

Page 3: ...o remove for access to the cooktop vent and utilities For installation with gas cooktops a 90 degree elbow must be connected to the cooktop gas inlet see diagram below to avoid interference with the r...

Page 4: ...t with in line Blower Duct Work Under Floor wall Exhaust ILHSF series in line blower 3 1 4 X 10 to round transition Duct work Duct work Outside wall Cooktop Wall cap on outside wall Raised vent Raised...

Page 5: ...ack draft never decrease the duct size over the run Do not rely on duct tape alone to seal duct joints Fasten all connections with sheet metal screws and tape all joints with certified silver tape or...

Page 6: ...ting location Bottom Exhaust Location 3 1 4 X 10 C L C L C L 1 7 8 48 mm 1 7 8 48 mm Front View Bottom View 14 3 8 365 mm Back of unit lines up with back of cutout RV 8 3 8 213 mm from back of RV cuto...

Page 7: ...e equivalent length of each 90 elbow is 15 feet The equivalent length of 45 elbow is 2 feet The equivalent length of the transition is 4 feet The total equivalent length of the above components is 15...

Reviews: