7
Installation Specifications
Top View - Downdraft ERV3015 with Slide-In, Self-Rimming Installation,
3” Side Panels Installed - Cabinet Depths 23 3/8” to 26 3/8”
Top View - Downdraft ERV3015 with Slide-In, Self-Rimming Installation,
3” Side Panels Removed - Min. Required Cabinet Depth: 26 3/8”
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
downdraft vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (1.0 cm)
countertop overhang
1” min. (2.6 cm)
to any combustibles
above counter both sides
20 3/8”
(51.8 cm)
to
23 3/8”
(59.4 cm)
20 3/8”
(51.8 cm)
2 5/8” (6.7 cm)
Countertop front
Max.
overhang
1 5/8”
(4.1 cm)
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
downdraft vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)
2
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (1.0 cm)
countertop overhang
1” min. (2.6 cm)
to any combustibles
above counter both sides
23 3/8”
(59.4 cm)
2 5/8” (6.7 cm)
Countertop front
Max.
overhang
1 5/8”
(4.1 cm)
Cabinet Cutouts for Self-Rimming Installation with Downdraft Vent (Models RNR30NIx and RNR30NIFx Only)
2
To create a “built-in look” on the front of the
cabinet, this dimension may be changed to 29 1/4”
(74.3 cm), with the width at the notches remaining
30 1/16”. This configuration is only for models
RNR30NIx and RNR30NIFx with the side panels
behind the door removed.
•
Trim kit PN ATKR30SR is required for proper
installation of a downdraft vent with this range.
•
The self-rimming installation of the RNR30NI[F]x
range and ERV3015 downdraft vent create a “built-
in” look where the range trim overlaps and rests
on the countertop on both sides and the downdraft
vent trim overlaps the countertop in back. The
ATKR30SR trim kit, installed on the back of the
range, will cover the front of the downdraft vent
chassis.
•
Observe all vertical cabinet clearances on
page 5.
•
A self-rimming countertop configuration is required
for downdraft vent installation. On installations
with a downdraft vent, when sliding the range into
position, it will stop when the rear of the control
panel or side panels contact the notches toward
the front of the countertop.
34 3/4”
(88.3 cm)
to
36 7/8”
(93.7 cm)
(see diagrams)
Countertop
1 5/8 (41.1 cm)
max. thickness
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.