5
Installation Preparation
1. Prepare the mounting surface and reinforce it if neces-
sary according to the
Blower Location and Mounting
specifications on the facing page.
2. Make a cutout in the center of the mounting location
according to
Figure 1
on the facing page.
Installation Requirements
Exhaust, no obstructions
within 15” (38 cm)
Roof
Wall
Blower
Blower
Duct and wiring passing
through cutout
Example of Roof
Installation
Example of Wall
Installation
Figure 3: Installation with Roof Curb (for flat roofs)
Roof curb
Blower
exhaust
Prevailing
wind
33 1/2”
(85.1 cm)
2”
(5.1 cm)
26"
(66.0 cm)
30 1/2”
(77.6 cm)
6”
(15.2 cm)
2”
(5.1 cm)
REMP16 Roof Curb
25 1/2"
(64.8 cm)
2"
(5.1 cm)
19"
(48.3 cm)
23 ¼"
(59.1 cm)
6"
(15.2 cm)
2"
(5.1 cm)
REMP3 Roof Curb
Figure 4
Figure 2
3. On roofs with a pitch of 2:12 or less, construct a roof
curb according to the specifications below. Attach it to
the mounting surface and seal it around the base.
NOTE:
Range hood installations with a very short
duct run are not recommended due to noise. When a
range hood installation can accommodate a short duct
run, Dacor instead recommends installation of a range
hood with an integral blower instead of using a REMP
series blower.