Installation Instructions

Installing the Burner Components

 WARNING

• 

Never attempt to operate the cooktop with any of the 

burner parts removed.

• 

Do not attempt to adjust the burner air mixture set-

tings. All adjustments are preset at the factory.

1.  Remove the burner heads, burner rings, burner caps 

and grates from their shipping packages.

2.  Install the burners as shown. When installing the burn-

er components, twist each piece back and forth slightly 

until it drops completely into place. The burners will 

not operate properly unless all of the burner pieces are 

properly seated.

3.  Gently set the grates on top of the spill tray. Make sure 

that the rubber feet are positioned in the dimples.

Burner Ring Installation Detail

Cooktop Burner Components

Verifying Proper Operation

 WARNING

• 

Make sure that power to the electrical outlet is turned 

off at the circuit breaker panel or fuse box and that 

the gas is turned off at the gas supply valve before 

proceeding.

• 

The cooktop must be properly grounded at all times 

when electrical power is applied. 

Prior to operating the cooktop, read the accompanying use 

and care manual carefully.
1.  Make sure all the cooktop burner controls are in the 

OFF

 position.

2.  Connect the power cord to the electrical outlet.
3.  Turn on power to the electrical outlet at the circuit 

breaker or fuse box.

4.  Depress and turn one burner control knob at a time 

slowly counterclockwise to the 

HIGH

 position. Verify 

that the associated burner igniter sparks, then return 

the knob to the 

OFF

 position. Repeat for all of the 

remaining control knobs.

5.  Turn on the gas supply valve.
6.  Perform the following ignition test for all of the burners:

• 

Press and turn the control knob slowly counter-

clockwise to the 

HIGH

 position. Only the selected 

burner will spark. It may take up to four seconds 

for the burner to ignite, at which time the igniter 

will stop sparking. If ignition does not occur within 

four seconds, turn off the knob, wait for at least five 

minutes to allow any gas to dissipate, then repeat 

the test.

       

Continued...

Off position

Knob

Knob position 

indicator

(polished surface)

Burner

designation

Light and high

position

Area of

operation

Low

position

Burner Control Knob

Summary of Contents for Preference SGM304

Page 1: ...Installation Instructions Models SGM304 SGM365 SGM466 Gas Cooktop Part No 65141 Rev L ...

Page 2: ...allation instructions for future reference and the local electrical inspector s use NOTE Dacor is not responsible for service required to correct a faulty installation 2007 Dacor all rights reserved If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under warranty call the Dacor Distincti...

Page 3: ...PORTANT If you smell gas Do not use or light any appliance Do not touch any electrical switch or use any electri cal devices including the telephone in your building From a neighbor s phone immediately call the gas supplier Follow the gas supplier s instructions If you cannot contact the gas supplier call the fire department DANGER IMPORTANT Do not store or use combustible flammable or explosive v...

Page 4: ...op Do not climb on any part of the appliance WARNING General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety precau tions including the following Do not leave children alone or unattended in the area around the cooktop Do not allow children to play with the controls or touch other parts of the cooktop Do not store i...

Page 5: ...is 19 1 2 49 5 cm 21 53 3 cm 4 10 2 cm chassis height 36 91 4 cm 33 1 2 85 1 cm including embosses in side of chassis 19 1 2 49 5 cm 21 53 3 cm 1 5 8 4 1 cm bottom of base to cooking surface 4 10 2 cm chassis height including embosses screws in side of chassis 46 116 8 cm 44 5 8 113 3 cm 19 1 2 49 5 cm 21 53 3 cm 1 5 8 4 1 cm bottom of base to cooking surface 4 10 2 cm chassis height Model SGM466 ...

Page 6: ...hassis Bottom Diagram for label location Units equipped for high altitude operation have an H at the end of the model number listed on the product data label Check your local building codes for the proper method of installation In the absence of local codes this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 An external manual shut off valve must be...

Page 7: ...the cabinet below allow for the routing of gas and electrical service behind it The installation must allow for the following Access to the gas shut off valve and regulator when the unit is installed Access to the electrical outlet when the cooktop is in place The 40 101 6 cm power cord must be able to reach the electrical outlet Access to the underside of the cooktop for service and inspection pu...

Page 8: ... all dimensions against the table below and the correct diagram before cut ting the countertop Countertop Dimensions Installation Type Cutout Diagram C Minimum D E F G H SGM304 without raised vent Figure 1 Square 2 7 8 7 3 cm 19 3 4 50 2 cm 27 3 4 68 6 cm NA NA NA SGM304 with ERV30 PRV30 Figure 1 Square 3 8 1 0 cm 22 1 2 57 2 cm 27 3 4 68 6 cm NA NA NA SGM304 with RV30 Figure 1 Square 5 8 1 6 cm 2...

Page 9: ...stible surface Rear wall 1 7 8 min 4 8 cm E C D H H G F 7 1 2 19 1 cm min to combustible side wall above countertop both sides Vertical combustible surface Rear wall 1 7 8 min 4 8 cm 4 1 4 10 8 cm min from mounting surface to combustibles below cooktop chassis Installation Specifications Figure 1 Square Countertop Cutout Diagram Figure 2 Notched Countertop Cutout Diagram ...

Page 10: ...gas flow towards the cooktop Do not apply excessive pressure when tightening gas connections and fittings Do not use Teflon tape or plumber s putty on flexible gas line connections Test the gas lines for leaks as instructed before use Do not use a flame to check for leaks The maximum gas supply pressure to the regulator must never exceed 1 2 pounds per square inch psi or 3 5 kPa The cooktop and sh...

Page 11: ...re proceeding The cooktop must be properly grounded at all times when electrical power is applied Prior to operating the cooktop read the accompanying use and care manual carefully 1 Make sure all the cooktop burner controls are in the OFF position 2 Connect the power cord to the electrical outlet 3 Turn on power to the electrical outlet at the circuit breaker or fuse box 4 Depress and turn one bu...

Page 12: ...ll See inside cover for location Dacor is not responsible for the cost of correcting problems caused by a faulty installation Normal Flame Appearance Installation Checklist warning To ensure a safe and proper installation the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked Proper installation is the responsibility of the homeo...

Page 13: ... left rear right front 86408 Burner cap right rear 86523BM Burner ring right rear 86407 SGM365 Description Dacor Part Number Regulator 82540 Grate large 82925SB Grate small 62443SB Burner cap left front 72435BM Burner ring left front 86918 Burner cap left rear right front 86524BM Burner ring left rear right front 86408 Burner cap center rear right rear 86523BM Burner ring center rear right rear 86...

Page 14: ...12 Wiring Diagrams ...

Page 15: ...13 Wiring Diagrams ...

Page 16: ...14 Wiring Diagrams ...

Page 17: ...15 Notes ...

Page 18: ...16 Notes ...

Page 19: ......

Page 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com ...

Reviews: