9
Installation Instructions
Verifying Proper Operation
WARNING
Make sure that power to the electrical outlet is turned
•
off at the circuit breaker panel or fuse box and that
the gas is turned off at the gas supply valve before
proceeding.
The cooktop must be properly grounded at all times
•
when electrical power is applied.
Prior to operating the cooktop, read the accompanying use
and care manual carefully.
Make sure all the cooktop burner controls are in the
1.
OFF
position.
Connect the power cord to the electrical outlet.
2.
Turn on power to the electrical outlet at the circuit
3.
breaker or fuse box.
Depress and turn one burner control knob at a time
4.
slowly counterclockwise to the
HIGH
position. Verify
that the associated burner igniter sparks, then return
the knob to the
OFF
position. Repeat for all of the
remaining control knobs.
Turn on the gas supply valve.
5.
Perform the following ignition test for all of the burners:
6.
Press and turn the control knob
•
slowly counter-
clockwise to the
HIGH
position. Only the selected
burner will spark. It may take up to four seconds
for the burner to ignite, at which time the igniter
will stop sparking. If ignition does not occur within
four seconds, turn off the knob, wait for at least five
minutes to allow any gas to dissipate, then repeat
the test.
Once the burner lights, rotate the control knob
•
counterclockwise from
HIGH
to
LOW
to adjust the
flame height progressively. On dual burners turn
the control knob to the simmer setting and make
sure the low level flame can be adjusted.
When the unit is installed properly, the flame will
•
be steady. It will also have a sharp, blue inner cone
that will vary in length proportional to the burner
size. The flame will be reduced by the Smart
Flame™ fea-
ture under the
grate fingers to
increase grate
life.
NOTE: If the cooktop does not operate properly, follow
these troubleshooting steps:
Verify that power and gas are supplied to the cooktop.
•
Check to make sure that the power plug is connected
•
to the electrical outlet and that power is turned on at
the circuit breaker or fuse box.
Check to make sure that the burners are properly
•
seated.
If the burner continues to spark after ignition without
•
stopping, have a licensed electrician check the electri-
cal outlet for proper grounding or reversed polarity.
Repeat the above burner ignition test.
•
If the appliance still does not work, contact Dacor
•
Distinctive Service at (877) 337-3226. Do not attempt
to repair the appliance yourself. If you need service, be
sure to have the model and serial numbers available
when you call. See inside cover for location.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
LOW
position
HIGH
position
Area of
operation
Knob position
indicator
Burner normally
lights when knob
reachs this
position
ON
LOW
position
HIGH
position
LOW
position
HIGH
position
Knob position
indicator
Area of
operation
Area of
operation
Burner normally
lights when knob
reachs this
position
ON
Single Burner Control Knob
Dual Burner Control Knob
Normal Flame Appearance