![Dacor PMOR3021B Service Manual Download Page 36](http://html1.mh-extra.com/html/dacor/pmor3021b/pmor3021b_service-manual_3255577036.webp)
34
PMOR3021S
PMOR3021B
PMOR3021R
1. Disconnect the power supply cord.
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60 seconds.
4. Remove the five (5) screws holding the bottom sush to
the base cover.
5. Remove the three (3) screws holding the base cover to
the oven cavity front face plate.
HOOD LAMP SOCKETS REMOVAL
6. Open the base cover.
7. Screw the hood lamp off from the lamp socket.
8. Disconnect the wire leads from the lamp socket.
9. Push the tab holding the lamp socket to the hood lamp
mount.
10.Remove the lamp socket from the hood lamp mount.
11. Now, the lamp socket is free.
1. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Remove one (1) screw holding the hood duct R to the
oven cavity top plate.
5. Release the hood duct R from the oven cavity top plate
OVEN LAMP AND LAMP SOCKET REMOVAL
by lifting it up.
6. Disconnect the wire leads from the lamp socket.
7. Remove the oven lamp angle from the hood duct R by
pushing the two (2) tabs holding the oven lamp angle..
8. Screw the oven lamp off from the lamp socket.
9. Now, the oven lamp is free.
10.Remove the lamp socket from the oven lamp angle by
pushing the tab holding the lamp socket.
11.Now, the oven lamp socket is free.
1. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNECTORS TO THE TERMINALS, IN-
STALL THE POSITIVE LOCK
®
SO THAT THE
LEVER FACES YOU.
POSITIVE LOCK
®
CONNECTOR (NO-CASE TYPE) REMOVAL
Positive lock
®
connector
1. Disconnect the power supply cord.
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60 seconds.
4. Remove three (3) screws holding the hood louver to
oven cavity front face plate.
5. Remove the hood louver from the oven by pushing the
right and left tabs of the hood louver. (Refer to procedure
of "HOOD LOUVER REMOVAL")
6. Remove one (1) screw holding the control panel to the
oven cavity front face plate.
7. Release the control panel from the oven cavity front face
plate by lifting it up.
8. Disconnect the wire leads from the relay.
9. Disconnect all connectors from the control unit.
10. Remove the control panel assembly from the oven.
11.Now, the control panel assembly is free.
12.Disconnect the connector CN-G from the control unit.
13.Remove three (3) screws holding the control unit to the
key fixing angle.
14.Release the two (2) tabs holding the control unit to the
key fixing plate.
CONTROL PANEL ASSEMBLY, CONTROL UNIT AND KEY UNIT REMOVAL
Terminal
Push
Pull down
1
2
Lever
Positive lock®
connector
15.Now, the control unit is free.
16.Remove the one (1) screw holding the key fixing angle to
the control panel.
17.Release the seven (7) tabs holding the key fixing angle
to the control panel.
18.Remove the key fixing angle from the control panel.
19.Remove the key unit from the key fixing angle.
20.Now, the key unit is free
NOTES FOR KEY UNIT REPLACEMENT
1. Do not reuse the torn key unit because the performance
of the adhesive becomes weak.
2. Before attaching a new key unit, wipe off remaining
adhesive on the key fixing angle surfaces completely
with a soft cloth soaked in alcohol.
3. When attaching the key unit to the key fixing angle,
adjust the upper edge and right edge of the key unit to the
correct position of key fixing angle.
4. Stick the key unit firmly to the key fixing angle by rubbing
with soft cloth not to scratch.