8
9
p
erforManCe
d
ata
Standard No. 42: Aesthetic Effects
Parameter
uSEPA
MCL
Influent
Challenge Concentration
Influent
Average
Effluent
% Reduction
Min. Required
Reduction
Average
Maximum
Average
Minimum
Cholorine
–
2.0 mg/L ± 10%
1.88 mg/L
<0.05136364 mg/L
0.06 mg/L
>97.26
96.84
50%
Taste and Odor
–
–
–
–
–
–
–
–
Particulate**
–
at least 10,000 particles/ml
5,700,000 #/ml
30,583 #/ml
69,000 #/ml
99.52
98.94
85%
Standard No. 53: Health Effects
Parameter
uSEPA
MCL
Influent
Challenge Concentration
Influent
Average
Effluent
% Reduction
Min. Required
Reduction
Average
Maximum
Average
Minimum
Turbidity
1 NTU**
11 ± 1 NTU***
10.7 NTU
0.31 NTU
.049 NTU
97.09
95.20
0.5 NTU
Cysts
99.5%
Reduction
Minimum 50,000/L
166,500 #/L
<1 #/L
<1 #/L
>99.99
>99.99
>99.99%
Asbestos
99%
Reduction
10
7
10
8
fibers/L; fibers > micrometers
in length
155 MF/L
<1 MF/L
<1 MF/L
>99.99
>99.99
99%
Lead at pH 6.5
0.015 mg/L
0.15 mg/L +10%
0.153 mg/L
<.001 mg/L
<.001 mg/L
>99.35
>99.29
0.10 mg/L
Lead at pH 8.5
0.015 mg/L
0.15 mg/L +10%
0.150 mg/L
<.001 mg/L
<.001 mg/L
>99.33
>99.29
0.10 mg/L
Mercury at pH 6.5
0.002 mg/L
.006 mg/L ± 10%
0.006 mg/L
0.0003 mg/L
0.0005 mg/L
95.70
90.91
0.002 mg/L
Mercury at pH 8.5
0.002 mg/L
.006 mg/L ± 10%
0.006 mg/L
0.0008 mg/L
0.0015 mg/L
86.22
75.93
0.002 mg/L
Atrazine
0.003 mg/L
0.009 mg/L + 10%
0.009 mg/L
<0.002 mg/L
0.002 mg/L
76.99
75.31
0.003 mg/L
Benzene
0.005 mg/L
0.015 mg/L ± 10%
0.014 mg/L
0.0006 mg/L
0.0011 mg/L
95.71
92.14
0.005 mg/L
Carbofuran
0.04 mg/L
0.08 mg/L ± 10%
0.081 mg/L
<0.001 mg/L
<0.001 mg/L
98.74
98.46
0.04 mg/L
p-Dichlorobenzene
0.075 mg/L
.225 mg/L ± 10%
0.208 mg/L
<0.0005 mg/L
<0.0005 mg/L
99.76
99.74
0.075 mg/L
Lindane
0.0002
mg/L
0.002 mg/L ± 10%
0.002 mg/L
0.000 mg/L
<0.0001 mg/L
98.72
96.50
0.0002 mg/L
Toxaphene
0.003 mg/L
0.015 ± 10%
0.015 mg/L
<0.001 mg/L
<0.001 mg/L
92.97
91.67
0.003 mg/L
* Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp. of 68° + 5°F (20° + 3°C)
** Measurement in Particules/ml. Particules used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity Units
The AquaClean™ retractable water filtration system uses an AFF3
replacement cartridge. Timely replacement of filter cartridge is
essential for performance satisfaction from this filtration system.
Please refer to the applicable section of your Use and Care
Guide for general operation, maintenance requirements and
troubleshooting.
This system has been tested according to ANSI/NSF 42 and 53
for reduction of the substances listed above. The concentration
of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in ANSI/NSF 42
and 53.
s
peCifiCations
Rated Flow:
.78 gpm (2.9 L/min)
Min. Op. Temp: 33° F (.6° C)
Max. Op. Temp: 100° F (38° C)
Min. Op. Press: 35 psi (241 kPA)
Max. Op. Press: 120 psi (827 kPA)
System tested and certified by NSF International
against NSF/ANSI Std 42 for the reduction of Chlorine
Taste and Odor, Particulate Class I and against NSF/
ANSI 53 for the reduction of Cysts, Turbidity,Asbestos,
Mercury, Lead, Benzene, p-Diclorobenzene,
Carbofuran
General use Conditions
Read this Performance Data Sheet and compare the capabilities
of this unit with your actual water treatment needs.
DO NOT use this product where water is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system. System certified for cyst reduction
may be used on disinfected water that may contain filterable
cysts.
uSE ONLY WITH COLD WATER SuPPLY. CHECK FOR
COMPLIANCE WITH THE STATE AND LOCAL LAWS AND
REGuLATIONS.