background image

Door Reversibility 

The door swing of these units can be reversed. The 
door swing should be changed before installation. 
Refer to the Installation Instructions for further 
information on the procedure. 

 

Control Panel 

The cold control and light switch are easily replaced by 
first removing enough shelves to expose the capillary 
bulb retainer clip. 
Remove the retainer clip to expose the end of the 
capillary. The thermostat capillary is routed through a 
plastic sleeve. Carefully pull the capillary through the 
sleeve to remove. Remove the two Phillips screws 
securing the control panel above. Slide the control 
panel forward until the cold control electrical connector 
plug is exposed. When reinstalling capillary, make 
certain the bulb is captured behind the retaining clip. 

When reinstalling, note the longer screws hold the 
retaining clip while the shorter screws secure the 
control panel. 
 

Evaporator 

The evaporator is foamed into the interior back wall of 
the unit and is not serviceable. 
 

Condenser Fan 

To access the compressor, relay, overload, run 
capacitor, condenser and condenser fan, remove the 
machine compartment cover, held by 3 Phillips 
screws. The condenser fan is replaced by first 
removing two Phillips screws and plastic bushings at 
the base of condenser fan bracket. 

Slide the bracket, motor, and fan assembly to the left 
and out of the unit. Fan wiring is disconnected at 
terminals inside compressor cover. When reinstalling 
new fan motor, first remove white plastic clips to permit 
black rubber bushings to be fully seated. 

 