background image

6

Installation Specifications

Install a Support Platform in the 

Cabinet

Provide a platform (100 lb. load capacity) within the cabinet 
upon which the warming drawer will be supported. The 
platform must be installed level and straight. The top edge 
of the platform must be flush with the cutout at the front of 
the cabinet. There are no provisions to level the warming 
drawer after it has been installed. 3/4” (19 mm) thick 
plywood is recommended.

NOtE: 

If the drawer is not installed in a level fashion, the 
drawer may slide open on its own or may not seal 
tightly, allowing heat to escape and resulting in poor 
warming drawer performance.

Support

platform

Chassis

face

The warming drawer is supplied with a power cord 

• 

terminated by a three-prong plug. Plug it directly into a 
dedicated, grounded, three prong, electrical outlet. Do 
not use an extension cord.

The correct voltage, frequency and amperage must be 

• 

supplied to the electrical outlet from a grounded, single 
phase circuit that is protected by a properly sized circuit 
breaker or time-delay fuse.

The required voltage, frequency and amperage ratings 

• 

are listed on the appliance data plate. The data plate 
is located inside the chassis drawer opening on the left 
side. Remove the drawer to expose it.

If the power supply requirements shown above do not 

• 

agree with those listed on the product data plate, use 
the requirements on the product data plate. 

It is the owner’s responsibility to ensure that the 

• 

electrical outlet is installed by a qualified electrician. 
The electrical installation must comply with the latest 
revision of the National Electric Code ANSI/NFPA 70 
and local codes and ordinances.

If the electrical service provided does not meet the 

• 

product specification, or does not conform to the NEC 
or local standards, do not proceed with the installation. 
Call a licensed electrician to correct the electrical 
service before proceeding.

Be certain to locate the electrical outlet in an 

• 

accessible location, so that the warming drawer may 
be easily unplugged in the event that service becomes 
necessary.

Electrical Power Supply 

Requirements

Nominal Electrical Supply Requirements

120 Vac, 60 Hz, 15 Amp. dedicated circuit

The warming drawer is supplied with a 40” (1016 mm) 
power cord with a three prong grounded plug.

total Connected Load

 

0.5 kW (4 Amp.)

Three-Prong Plug

Three-Prong  

Grounded Outlet

Summary of Contents for Epicure EWD24

Page 1: ...Installation Instructions Warming Drawer Models EWD24 EWD27 EWD30 EWD36 IWD24 IWD27 IWD30 MWDV27 MWDH27 MWDV30 MWDH30 MRWD27 MRWD30 PWD27 PWD30 Part No 102345 Rev D ...

Page 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2007 Dacor all rights reserved ...

Page 3: ...ry or death caution Hazards or unsafe practices that COULD result in minor personal injury or property damage Before You Begin Before You Begin 1 Important Safety Instructions 1 General Safety Precautions 2 Installation Specifications 3 Verifying the Package Contents 3 Installation Planning 3 Install a Support Platform in the Cabinet 6 Electrical Power Supply Requirements 6 Important Safety Instru...

Page 4: ... using your appliance follow basic precautions including the following Read this manual completely before using this appliance Use this appliance only for its intended use as described in this manual Use it only to warm food and heat plates and utensils It is not designed for commercial industrial or laboratory use Do not store or install this appliance outdoors unless otherwise noted in these ins...

Page 5: ...he drawer Cabinet cutout dimensions must be used as indicated All contact surfaces between the appliance and the cabinet must be solid and level The drawer support platform must be flush with the bottom edge of the cabinet cutout Make certain that you have everything necessary to ensure a proper installation before proceeding Installation Specifications Warming Drawer Model No Dimension A Drawer F...

Page 6: ...open 5 64 2mm 23 13 16 605 mm B C Overall Dimensions Top View EWD Series Shown 10 1 8 257 mm A Drawer Face Dimensions MW Series Shown 3 5 16 84mm 1 25mm EWO 1 25mm 1 5 16 33mm MWO 1 25mm 2 3 16 56mm PWO 3 7 16 87mm EW 3 1 4 83mm PW 2 1 4 57mm MW 1 25mm 1 5 32 29mm 1 1 8 29mm 3 7 16 87 mm EWD 3 1 4 83 mm MRWD MWDH V 1 25mm 1 25mm PWD 2 1 4 57 mm 1 25mm 1 25mm Handle Dimensions 10 254 mm 9 229 mm 1 ...

Page 7: ...4 Min 610 mm Model A Cutout Width B Min Width to Adjacent Doors Drawers C Cutout Height D Min Vertical Gap Between Cutouts IWD24 22 1 4 565 mm 24 1 4 616 mm 9 1 8 232 mm 1 1 16 27 mm EWD24 EWD27 25 1 4 641 mm 27 1 4 692 mm IWD27 MWDH27 MWDV27 MRWD27 PWD27 EWD30 28 1 4 717 mm 30 1 4 768 mm IWD30 MWDH30 MWDV30 MRWD30 PWD30 EWD36 34 1 4 870 mm 36 1 4 921 mm Bare minimum spacing shown to allow for ven...

Page 8: ...ncy and amperage ratings are listed on the appliance data plate The data plate is located inside the chassis drawer opening on the left side Remove the drawer to expose it If the power supply requirements shown above do not agree with those listed on the product data plate use the requirements on the product data plate It is the owner s responsibility to ensure that the electrical outlet is instal...

Page 9: ... both sides and pull it free 4 For safety push both drawer slides into the drawer 5 opening Installation Instructions Installing the Chassis Grasp the warming drawer chassis on opposite 1 sides and slide it partially into the cabinet opening Temporarily support the chassis in place so that it will not tilt or fall From an adjoining cabinet reach in behind the drawer 2 and pull the power cord until...

Page 10: ...6 Has the chassis been properly fastened to the mounting platform and sides of the cabinet See page 7 Has the drawer been properly installed Has proper operation been verified Have any problems been noted on the warranty card or during the on line warranty activation Has the warranty been activated on line or the warranty card filled out completely and mailed Re installing the Drawer Pull the draw...

Page 11: ......

Page 12: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com ...