IMPORTANT: 

1.  If the electrical supply circuit 

does not have a grounding-

type receptacle, it is the 

responsibility of the customer 

to have the existing receptacle 

changed by an electrician to a 

properly grounded receptacle.

2.  The power supply must be 

properly polarized. Reverse 

polarity will result in continuous 

sparking of the electrodes, 

even after flame ignition. If the 

power supply is not properly 

polarized, it is the responsibility 

of the customer to have the 

polarity corrected.

3.  If there is any doubt as to 

whether the wall receptacle 

is properly grounded  or 

polarized, have it checked by 

a qualified electrician prior to 

installing the cooktop.

4.  Do not plug the cooktop into 

Ground Fault Circuit Interrupter 

(GFCI) receptacles. The 

cooktop spark ignition module 

can cause a GFCI to trip.

Installing the Cooktop

IMPORTANT: 

Do not use a hardening compound 

or caulking to permanently seal the 

cooktop into place, as the unit must 

be readily removable for service. 

If such a hardening compound is 

used, removal of the unit will be at 

the customer’s expense.

Place and center the cooktop within the cutout. 

Secure the cooktop to the countertop utilizing 

the two (2) hold-down 1/4" x 20 x 1 1/2" bolts 

and flat washers provided. Do not over-tighten 

the bolts.

Connecting the Gas

WARNINGS: 

1.  The maximum gas supply 

pressure to the regulator must 

not exceed 1/2 pound per 

square inch.

2.  Verify that the proper gas 

supply has been provided.

3.  Do not apply excessive 

pressure when tightening 

connections and fittings.

4.  Do not use plumber's putty or 

Teflon tape on gas compression 

connections. It can defeat 

the proper sealing of these 

fittings. Use plumber's putty or 

Teflon tape only on pipe thread 

fittings.

5.  Turn all cooktop control valves 

to the “OFF” position, then turn 

on the gas supply. Check all 

supply lines and connections 

for leaks using a soap and 

water solution. Do not use a 

flame to check for leaks. After 

verifying that there are no gas 

leaks, turn off the gas supply 

to the cooktop by turning the 

gas shut-off valve to the off 

position. Leak testing of the 

appliance shall be conducted 

according to the manufacturer’s 

instructions.

6.  For LP gas installations, the 

LP gas tank must have its own 

high-pressure regulator. This 

is in addition to the pressure 

regulator supplied with the 

cooktop.

The gas inlet for the cooktop is located on the 

bottom, at the right rear of the chassis. Attach 

the gas pressure regulator (included with the 

cooktop) to the cooktop pipe nipple inlet. For 

tight installations, the regulator may be installed 

upstream from the pipe nipple, anywhere 

between the shut-off valve and the cooktop.  

Install a gas shut-off valve (not included with 

the cooktop) in the main gas supply line in 

an accessible location under the cooktop.  

Complete connection of the gas supply to 

the cooktop by installing 1/2 inch flexible gas 

line (not included with the cooktop) between 

the pressure regulator and the shut-off valve. 

The ESG has a 3/4" (19mm) diameter pipe 

nipple inlet. All models are compatible with 1/2" 

(13mm) house piping.

IMPORTANT:

To prevent damage to the gas 

pressure regulator, install the 

regulator only after the cooktop is 

mounted in its permanent position. 

Ensure that the arrow on the 

regulator points in the direction of 

the gas flow towards the cooktop.

Installing the Burner Components

Remove the brass burner rings, porcelain burner 

caps, and porcelain grates from their shipping 

packages. Place each burner ring onto its 

corresponding burner base, being certain that 

the five alignment tabs slide into the matching 

notches in the base. Set each porcelain burner 

cap on top of its corresponding burner ring. 

Place each grate onto the cooktop, being certain 

that the rubber feet are positioned in the locating 

dimples.

Grate

Burner Cap

Burner Ring

Top Frame

Burner Head (Fixed)

Burner Components

WARNING: 

Never attempt to operate the 

cooktop with any of the burner 

rings, burner caps or grates 

removed.

Connecting the Electrical

WARNINGS:

1.  Do not use or attempt to use 

this appliance in the event of a 

power failure.

2.  Verify that the proper electrical 

power supply has been 

provided.

3.  Verify that the electrical 

supply matches the ratings 

found on the appliance data 

plate (located on the rear of 

the cooktop chassis) before 

proceeding.

4.  This appliance must be 

connected to a grounded, 

metallic, permanent wiring 

system. Alternatively, a 

grounding conductor should 

be connected to the grounding 

terminal or lead on the 

appliance. Failure to do so may 

result in an electrical shock 

hazard.

5.  Do not use an extension cord 

with this appliance. Such use 

may result in fire, electrical 

shock, or other personal injury.

6.  Do not install a fuse in the 

neutral or ground circuit. A fuse 

in the neutral or ground circuit 

may result in an electrical 

shock hazard.

7.  Do not ground this appliance to 

a gas supply pipe or hot water 

pipe.

Summary of Contents for Epicure ESG366

Page 1: ...contents Page 2 STEP 2 Planning the installation Page 2 4 STEP 3 Gas and electrical supply requirements Page 4 5 STEP 4 Installing the cooktop Page 5 STEP 5 Connecting the gas Page 5 STEP 6 Installing...

Page 2: ...appliance must not be used in combination with surface countertop ventilation systems The use of an overhead hood is recommended for ventilation 8 This appliance must be installed with the gas pressur...

Page 3: ...nsions Installations with less than 2 1 2 64mm from the rear of the cooktop to a combustible backsplash must use Dacor Backguard model s AEB3609 AEB3612 AEB4809 AEB4812 or non combustible material Ref...

Page 4: ...G366 16 5 8 422mm ESG486 20 13 16 529mm 8 203mm 6 152mm 24 610mm 12 9 16 319mm Base Cabinet Preparation Top View 21 3 8 543mm 28 3 16 716mm ESG366 34 3 4 883mm ESG486 46 1168mm 5 8 16mm ESG366 36 914m...

Page 5: ...P cooktops should be special ordered from the factory Liquid propane units are identified by the LP designation at the end of the model number 3 Under extenuating circumstances cooktops may be field c...

Page 6: ...e cooktop is located on the bottom at the right rear of the chassis Attach the gas pressure regulator included with the cooktop to the cooktop pipe nipple inlet For tight installations the regulator m...

Page 7: ...he HIGH position Verify that all ignitors spark continuously then return the knob to the OFF position Repeat for all knobs Turn on the main gas supply to the cooktop by opening the gas shut off valve...

Page 8: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093...

Reviews: