background image

5

Installation Specifications

Any openings in the wall behind the appliance or in the 

• 

floor underneath it must be sealed.
If cabinet storage space is to be provided directly 

• 

above the range, the risk of personal injury may be 

reduced by installing a ventilating hood that projects 

horizontally a minimum of 5 inches beyond the face of 

the cabinets.

Cabinet Layout

 WARNING

Failure to meet or exceed the maximum and minimum 

dimensions/clearances stated may result in a fire hazard.

Carefully check the location where the range is to be 

• 

installed. For best performance, the range should be 

placed away from drafts that may be caused by doors, 

windows and heating and air conditioning outlets.
To reduce the risk of personal injury and to reduce 

• 

accumulated smoke in the room, Dacor strongly 

recommends installing a range hood. A range hood 

should project horizontally a minimum of five (5) inches 

beyond the face of the cabinets. If installing a range 

hood, see the range hood specifications for minimum 

clearances in addition to those stated below.
The range may be installed flush to the rear wall. 

• 

Dacor  

recommends installing a non-combustible material on 

the rear wall above the range and up to the vent hood. 

It is not necessary to install non-combustible materials 

behind the range below the countertop height.
Regardless of the type of back wall surface, 

• 

Note 2

2

 Cabinet/countertop depth is at discretion of customer 

but cabinet face SHALL NOT protrude further than rear 

of front panel. See product dimesions. 

3

 Consult local code for exact location requirements.

4

 Not applicable for cabinets more than a horizontal 

distance of 10” (254mm) from the edge of the range.

1

 Vertical to combustible surface from range grate level;

if installing an overhead vent hood, also check the hood

specifications for minimum required clearances. 

B

A

Non-combustible 

surface along 

back wall

recommended

10” (254mm Min.

to combustible side

walls above the range

(both sides)

Top of

finished

counter

Suggested 

location of 

utilities

3

30” (762mm)

Min.

1

13” (330mm)

Max.

4

18” (457mm)

Min.

1, 4

C

A

6

B

C

36” minimum 

(914 mm)

36” (914 mm) 

minimum

37 1/8” (943 mm) 

maximum

Cabinet Cutout Dimensions

Self-Rimming Cutout Dimensions - 

Cabinet Depth Greater Than 24 Inches

5

Self-Rimming Cutout Dimensions - 

Cabinet Depth Exactly 24 Inches

5

non comubustible 

rear wall recommended

Countertop Height: Min: 35 1/2” (902 mm) 

                               Max: 37 5/8” (956 mm) 
Countertop Thickness: Max: 1 5/8” (41mm)

countertop opening

35 1/4” (895 mm)

36” (914 mm)

cabinet opening

below countertop

below countertop

Cabinet face

Notch countertop

overhang to width of

cabinets

10” Min. (254mm)

to any combustibles 

above counter both sides

Countertop overhang 

2 1/8” (54 mm) Max. 

24”

 (610mm)

rear wall or

countertop edge

Countertop Thickness: Max: 1 5/8” (41mm)

countertop opening

cabinet opening

below countertop

below countertop

Cabinet face

Notch countertop

overhang to width of

cabinets

3/4” Min. (19mm)

 Countertop overhang

10” Min. (254mm)

to any combustibles 

above counter both sides

Countertop overhang 

2 1/8” (54mm) Max. 

24 1/8”

 (613mm)

Countertop Height: Min: 35 1/2” (902 mm) 

                               Max: 37 5/8” (956 mm) 

35 1/4” (895 mm)

36” (914 mm)

5

 Model ER36GI only. Included self-rimming trim kit 

allows trim to overlap countertop.

6

 See cutout dimensions above for self-rimming installations.

All tolerances: +1/16”, -0 (+1.6, -0 mm) 

unless otherwise stated

the range must not be installed 

or operated without the 

backguard in place.

Summary of Contents for Epicure ER36GISCH

Page 1: ...ctions Epicure 36 Inch Gas Range Part No 106554 Rev D THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1 STANDARD FOR HOUSEHOLD GAS COOKING APPLIANCES For use with mode...

Page 2: ...Team For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line Whenever you call have the model and serial number of the appliance ready The model and serial number are on...

Page 3: ...e prongs off the power cable plug and discard them Cut the power cable off and discard it separately from the old appliance WARNING WARNING NEVER use this appliance as a space heater to heat or warm t...

Page 4: ...r leave this appliance unattended when in use Do not leave children or pets alone or unattended in the area around the range Do not allow children to play with the controls pull on the handle or touch...

Page 5: ...nt panel7 26 3 4 679 mm 27 13 16 706 mm 29 736 mm 24 5 8 625 mm ER36G Full stainless steel side panels ER36GI Partial stainless steel side panel Grates extend 1 above trim Product width 35 7 8 911 mm...

Page 6: ...60 Hz 5 0 Amp Electrical Supply Requirements IMPORTANT The above information is for reference only If the information above differs from the information on the product data label on the appliance use...

Page 7: ...r cabinets more than a horizontal distance of 10 254mm from the edge of the range 1 Vertical to combustible surface from range grate level if installing an overhead vent hood also check the hood speci...

Page 8: ...e 2 small Oven racks 3 The following parts are are included with model ER36GI only They are for use with self rimming installations 3 Self rimming trim pieces left right rear 2 Self rimming side panel...

Page 9: ...e and discard the six 6 screws that hold the 2 backguard in place DO NOT remove the three screws toward the center on the back Slide the backguard up to remove Remove and discard the screws 5 each tha...

Page 10: ...on the bottom of each leg as shown below Use a level to make sure 2 that the range does not tilt front to back or side to side Readjust the legs as necessary Self Rimming Trim Installation cont Re at...

Page 11: ...arm on both hinges Lift the oven door to about a 15 angle from the vertical 3 position Hold the door with both hands just below the handle 4 Pull the door up and away from the oven Door Gripping Poin...

Page 12: ...r LP gas installations the LP gas tank must have its own high pressure regulator in addition to the pressure regulator installed on the range IMPORTANT The installed gas pressure regulator is pre set...

Page 13: ...sure that the notch on the bottom of each hinge rests on top of the lower lip of each hinge receptacle before attempting to open the oven door Rotate the hinge locks toward the front of the range imme...

Page 14: ...front burner only Standard Burner Assembly left rear right rear and both center burners STEP 1 Install dual burner ring on dual burner base Line up indentations on bottom of burner ring with pins on t...

Page 15: ...control knob and the oven ON indicator light should be illuminated Within 60 seconds the IR burner on the ceiling of the oven should ignite and begin to give off heat Turn the oven knob to the 11 OFF...

Page 16: ...nt Spark Module RR BURNER IGNITOR IGNITOR RF BURNER Single Point Spark Module LF BURNER IGNITOR IGNITOR LR BURNER W B W B 4 3 2 1 2 1 2 ER36G Controller Board P7 P3 3 4 5 6 7 8 9 10 11 12 P6 P11 P9 P1...

Page 17: ...15 Notes...

Page 18: ...16 Notes...

Page 19: ......

Page 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Reviews: