background image

9

I

nstallatIon

 I

nstructIons

1.  If the grill or cooktop fails to operate properly, 

ensure that the electrical power supply and gas 

supply are turned on and that all installation steps 

have been carefully followed. Call a qualified 

service technician if the grill still does not operate 

properly.

2.  The grill or cooktop and shut-off valve must be 

disconnected from the gas supply piping during 

any pressure testing exceeding 1/2 psi (3.5kPA).

3.  The grill or cooktop must be isolated from the gas 

supply piping by closing the shut-off valve during 

any pressure testing at or below 1/2 psi (3.5kPA).

4.  The top cover (canopy) is to be closed during the 

outdoor cooking gas appliance pre-heat period.

5.  Visually check the burner flame for carry over and 

proper operation.

6.  Proper flame operation will show a soft blue color 

and stable flame.

7.  Remove side burner cover before operating side 

burners.

8.  Never place the cover over operating side 

burners.

9.  Remove all shipping material from around side 

burners and side burner cover before operating 

side burners.

Lighting Instructions for Grills or Cooktops (Liquid Propane)

Turn ON the main tank valve, then turn all burners ON to the 

high position for approximately 20 seconds to allow the air in the 

system to purge from the grill and cooktop side burners. 

Once the gas has filled the lines the automatic electronic ignition 

system should ignite the burner.  If the system burners do not 

ignite within 20 seconds turn all burner controls to the OFF 

position and wait five minutes and attempt the ignition process 

again.

If the second or third attempt to ignite the burner is not successful 

then turn all burner controls to the OFF position.  Turn off the 

main gas line control valve or LP tank control valve and contract 

your authorized Dacor service agent to schedule a service call.

When installed properly, the flame will be steady and quiet.  

Flame adjustment will not be necessary, all grill and side burners 

are factory adjusted, for proper performance.

Read and understand the accompanying use and care manual 

prior to cooking with this appliance.  The use and care manual 

contains additional important safely, service and warranty 

information.

Specifications contained within are subject to change without 

notice. No liability is assumed for changes in specifications. 

Light & high position

Off position

Low position

Burner indicator light

Gas Control Knob

Verifying Proper Operation

 WARNINGS:

Summary of Contents for Epicure EOG36

Page 1: ...Installation Instructions Epicure Outdoor Grill For use with models EOG303 EOG36 EOG52 EOSB162 Part No 65249 Rev F...

Page 2: ...nal injury or death CAUTION CAUTION Hazards or unsafe practices which COULD result in minor personal injury or property damage CALIFORNIA PROPOSITION 65 WARNING The burning of gas cooking fuel generat...

Page 3: ...ubes for insects and insect nests A clogged tube can lead to a fire beneath the grill 9 Outdoor gas cooking appliances shall be used only outdoors and shall not be used in a building garage or any oth...

Page 4: ...52 28 711mm EOSB162 EOG303 36 52 Cutout Dimensions Top View 9 1 8 232mm 23 584mm 26 3 8 670mm 27 1 8 689mm 30 762mm 23 584mm EOG303 Overall Dimensions 9 1 8 232mm 23 584mm 26 3 8 670mm 27 1 8 689mm 36...

Page 5: ...trical connection gas shut off valve and pressure regulator are accessible inside the base enclosure 5 All MINIMUM electrical and gas dimensions are illustrated in the drawings within this manual Util...

Page 6: ...tilizing the deck screws and holes located along the vertical sides of the finish trim install them securely to the base enclosure countertop sub straight Install the trim before installing the grill...

Page 7: ...ne 11 Water Column 12 Water Column EOG52 Natural 4 Water Column 7 Water Column EOG52LP Liquid Propane 11 Water Column 12 Water Column EOSB162 Natural 4 Water Column 7 Water Column EOSB162LP Liquid Pro...

Page 8: ...ural gas installations will be connected to factory supplied natural gas regulator Refer to Natural gas connections in this manual for details 8 Inspect the gas line before and after installation Also...

Page 9: ...two fasteners located in the front right corner behind the horizontal support temporarily creating a 1 2 gap between the support rail and right side panel 4 Remove the EOG from its shipping carton and...

Page 10: ...utlet specified as applicable for connection No 5LP A 6 The cylinder supply system must be arranged for vapor withdrawal and provided with a listed overfilling prevention device 7 If the appliance is...

Page 11: ...ON the main tank valve then turn all burners ON to the high position for approximately 20 seconds to allow the air in the system to purge from the grill and cooktop side burners Once the gas has fill...

Page 12: ...0Hz HALOGEN LIGHTS TRANSFORMER BR 10W 12V RIGHT HALOGEN LIGHT BR BR W BK RED RED EOG303 Electrical Schematic GN W BK PLUGS IGNITION 4 POINT RE IGNITOR S2 S4 S3 S1 GN N A 3 4 S4 S3 2 1 S2 S1 LIGHTS IND...

Page 13: ...ONT SIDE BK BURNER REAR SIDE BK BURNER LEFT GRILL BK CENTER GRILL BURNER BK RIGHT GRILL BURNER BK O BK BK BK BK S2 BK BK W S1 W BK BK W BK BK BK S3 S4 S5 GN W W BK BK BK BK BK S6 BK BK BK BK BK W W W...

Page 14: ...he model and serial numbers when you call You ll find these numbers on the serial number plate located on the light shield in the fresh food compartment Contact a Dacor authorized servicer a Dacor dea...

Page 15: ......

Page 16: ...ained herein may be copied or used in whole or in part without the express written permission of Distinctive Appliances Inc 2006 Distinctive Appliances Inc all rights reserved Specifications contained...