Dacor Renaissance Wall Oven Service Guide
Page 16
Section 6
– Temperature Offset Calibration Instructions
Entering Calibration Mode
1) Press and hold the “
0
” and “
#
” keys. The display will show the word “PASS”.
2) Using the number keypad enter
6428
then press the Start key.
3) The display will change and read “
SLCE
” “
00
”. Quickly move to step 4.
4) Select the cooking mode that needs to be calibrated for example “
BAKE
“. Using the number keypad enter the
new calibration offset for example “
25
”. Using the number keypad press “#” to toggle between
+
and
–
. Press
the
START
key. This will lock the calibration. Press the
CANCEL - SECUR
E key to complete procedure.
Calibrating Additional Modes
5) Without
pressing
CANCEL - SECUR
E to complete: repeat step 4 and select new mode for example “
PURE
CONV
”.
6) Using the number keypad enter the new calibration offset for example “
20
”.
7) Using the number keypad press “
#
” to toggle between
+
and
-
.
8) Press
the
START
key. This will lock the calibration.
9) Press
the
CANCEL - SECUR
E key to complete procedure.