Dacor EORD227S Installation Instructions Manual Download Page 8

6

Installation Specifications

Installation Planning

 WARNING

Observe all governing codes and ordinances during plan-

ning and installation. Contact your local building depart-

ment for further information.

 IMPORtANt

• 

Locate the junction box so that the oven may be easily 

disconnected in the event that it needs to be removed 

from the wall completely for service.

• 

If the oven is not installed level it may deliver poor or 

inconsistent baking results.

• 

A qualified technician must complete the installation of 

this built-in appliance. Proper installation is the respon-

sibility of the customer.

• 

Carefully check the location where the oven is to be 

installed. The oven should be placed for convenient 

access. Make certain that electrical power, meeting 

the specifications on page 4, can be provided in the 

selected location.

Minimum interior cabinet depth: 24” (61.0 cm)

• 

Dacor recommends installing the electrical junction box 

in the one of the locations shown.

• 

Install the junction box in a location that allows the 

oven to be removed from the the cutout for service 

without being disconnected.

• 

Plan the installation so that all minimum clearances 

are met or exceeded. Dimensions shown provide mini-

mum clearances, unless otherwise noted. Be certain 

that proper clearance is provided for the oven door 

when it is in the open position according the 

Product 

Dimensions

.

• 

Cabinet cutout dimensions must be used as indicated. 

The specified minimum cabinet depth and width must 

be provided. The cabinet depth and width must com-

pletely enclose the recessed portion of the oven.

• 

All contact surfaces between the appliance and the 

cabinet must be solid and level. 

• 

Provide a platform within the cabinet to support the 

oven. It must be installed level and straight. The top 

edge of the platform must be flush with the cut out at 

the front of the cabinet. There are no provisions to level 

the oven after it has been installed. 3/4” (1.9 cm) thick 

plywood is recommended.

Model 

Number

Minimum Cabinet 

Width (N)

Minimum Cut Out 

Width (P)

Minimum Cut out 

Height (R)

EORS127/

MORS127

27” (68.6 cm)

25 1/2” (64.8 cm)

27 5/8” (70.2 cm)

EORS130/

MOCS130

30” (76.2 cm)

28 1/2” (72.4 cm)

EORS136

36” (91.4 cm)

34 1/2” (87.6 cm)

27 1/2” (69.9 cm)

EORX227/

MORX227

27” (68.6 cm)

25 1/2” (64.8 cm)

49 1/8” (124.8 cm)

EORX230/

MORX230

30” (76.2 cm)

28 1/2” (72.4 cm)

Cabinet Dimensions

X = Number of convection ovens, see page 3

Cabinet tolerances: +1/16 (1.6 mm), -0, unless otherwise stated.

Summary of Contents for EORD227S

Page 1: ...Installation Instructions Classic Wall Oven Models EOR MOR Part No 102579 Rev L...

Page 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2007 Dacor all rights reserved...

Page 3: ...Labels 1 General Safety Precautions 2 Customer Service Information 3 If You Need Help 3 Appliance Data Plate 3 Model Identification 3 Product Specifications 4 Power Supply Requirements 4 Product Dime...

Page 4: ...rd secure the oven to the cabinet using the supplied mounting screws WARNING General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance foll...

Page 5: ...ou call have the model and serial number of the appliance ready The model and serial number are printed on the appliance data plate Dacor Customer Service Phone 800 793 0093 U S A and Canada Monday Fr...

Page 6: ...0 kW 21 Amp MORS127 EORS130 MORS130 EORS136 5 3 kW 22 Amp EORS227 240 Vac 60 Hz 4 wire 40 Amp 7 8 kW 33 Amp MORS227 EORS230 MORS230 EORD227 240 Vac 60 Hz 4 wire 50 Amp 10 0 kW 42 Amp MORD227 EORD230...

Page 7: ...F A K L M E Chassis Notch Side View Control panel front Top of chassis Top of chassis Utility cutout Light cover Light cover Conduit 60 152 cm Long D Design Specifications 3 3 8 8 6 cm 1 2 5 cm 1 2 5...

Page 8: ...allation so that all minimum clearances are met or exceeded Dimensions shown provide mini mum clearances unless otherwise noted Be certain that proper clearance is provided for the oven door when it i...

Page 9: ...4 1 9 cm support platform 31 1 4 79 4 cm recommended 1 2 5 cm Min to bottom of cabinet door 1 2 5 cm Min to top of cabinet door 1 1 2 3 8 cm typical counter 1 2 5 cm Min to combustible floor 3 4 1 9...

Page 10: ...with 2 double ovens come with either 4 or 5 GlideRack oven rack 1 Broil grill and pan Remove the door s to reduce weight and make the oven easier to lift warning Do not attempt to disengage the hinge...

Page 11: ...the supplied appli ance conduit may be a smaller gage than the standard household wiring of the dedicated supply circuit They are suitable for connection to household wiring under the jurisdiction of...

Page 12: ...e Wire Electrical System Where Local Codes Permit warning Do not connect the green appliance conduit wire to the neutral white junction box wire unless local building codes permit 1 Separate the wires...

Page 13: ...be jumped with a minimum 4 AWG wire to establish continuity to ground note If the junction box has been properly grounded by a licensed electrician the green ground wire from the appliance conduit ma...

Page 14: ...il the rear edge of the oven frame is flush with the cabinet face and the oven is centered within the cut out Ensure that the electrical conduit slides through the opening in the cabinet platform or c...

Page 15: ...or on opposite sides and lift it until the door hinges are aligned with the openings in the oven frame 2 Holding the door at about a 30 angle from the horizon tal slide the hinges into the openings un...

Page 16: ...ker or fuse box and check the electrical connections Turn on power and repeat the above heating test If the appliance still does not work contact Dacor Distinctive Service at 877 337 3226 Do not attem...

Page 17: ...nded according to these instructions and in accordance with all applicable elec trical codes See pages 4 and 9 through 11 Is the oven secured into the cabinet with all the mount ing screws four 4 on s...

Page 18: ...16 Notes...

Page 19: ......

Page 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Reviews: