PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
4.3
cAbINEt/coUNtErtoP cUtoUt DImENsIoNs wIthoUt rAIsED VENt - toP VIEw
Model No.
B - Cutout Width
D - Hole Offset
EG366
36” (914 mm)
16 5/8” (422 mm)
EG486
48” (1219 mm)
20 13/16” (529 mm)
Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
EG366, EG486
Document # PG04-001
Revised 05/06/10 Page 3/4
Non-combustible
rear wall, rear of
mounting platform
10” (254 mm) min.
to combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
Increase countertop and overhang
additional 2 1/2” (64 mm) Min. for
combustible rear wall above
countertop
3/8” (13 mm)
countertop overhang
Hole 1/2” dia. (13 mm),
2 places, through platform
for hold down bolts
Gas/electrical utility cut-out in right rear corner of
mounting platform 8” W X 6” D (203 mm X 152 mm),
if gas and electrical are routed through bottom
1/2” (13 mm)
countertop
overhang
1” thick mounting platform Min.
Countertop
Countertop
1/2” (13 mm)
countertop
overhang
2” (51 mm)
1” (25 mm)
11 7/16”
(291 mm)
24 5/8”
(625 mm)
CL
D
D
B
CL
CL
CL
Gas connection and power cord may be
routed through bottom or back of chassis
Gas and electrical connections at
right rear section of chassis
36 Inch and 48 Inch wide
Epicure
®
Gas cooktops