background image

5

Plumbing Preparation

The water pressure must be between 20 and 120 psi 

• 

(138-827 kPa). The household hot water heater must 

supply a minimum of 120 °F water to the dishwasher 

location for best results.
Install a valve for the hot water supply line where it is 

• 

easily accessible after the dishwasher is installed. 
A flexible braided hot water inlet hose is highly 

• 

recommended for connection to the hot water supply. 

Connect it to the unit just prior to installation into the 

cabinet. The dishwasher ships with a 3/8” (10 mm) male 

compression fitting on the hot water inlet to facilitate 

installation.

Preparing the Drain

 CAUtION

Keep the factory installed high loop drain hose in

place to ensure proper dishwasher operation. Do not

cut, tie, strap or lower it. If it is necessary to lengthen

it, install an aftermarket drain extension kit, available

at most home improvement stores.

IMPORtANt:

 A drain hose is supplied with the product 

(see above). Should a longer drain hose be required, use a 

hose approved for detergents and high temperature water. 

The drain hose supplied with the dishwasher meets an 

AHAM DW-1 test standard. Longer drain hoses should not 

be longer than a total of 12 ft. in length.

You must install an air gap in the drain if the drain hose 

• 

is connected to household plumbing lower than 20 in. 

(50.8 cm) from the floor or if required by local codes. 

Plan for the air gap in the sink or countertop area 

adjacent to the dishwasher. A section of drain hose (not 

provided) needs to be installed from the air gap to the 

disposal or waste tee.
If an air gap is not required, the drain hose must be 

• 

installed to an inlet or waste tee above the drain trap in 

the household plumbing.
The drain hose supplied with the dishwasher should be 

• 

connected to a minimum 1/2 in. I.D. drain connection.

Preparing for Installation

 WARNING

The electrical power supply for the dishwasher must be 

installed only by a licensed electrician as specified below. 

It is the owner’s responsibility to ensure that the electrical 

connection of this appliance is performed by a licensed 

electrician.

Electrical Specifications

The electrical installation, including minimum supply 

wire size and grounding, must be in accordance with the 

National Electric code ANSI/NFPA* (or latest revision) and 

local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association  

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101

Power supply requirements:

The dishwasher requires a grounded, dedicated  

• 

120 Vac, 60 Hz circuit protected by a 15 Amp. circuit 

breaker or time delay fuse installed by a licensed 

electrician.
It must be located to the right or left of the cut-out, in an 

• 

adjacent cabinet, so that power can be disconnected 

without removing the dishwasher.
The ground terminal (or lead) on the appliance must be 

• 

connected to a grounded, metallic, permanent wiring 

system or grounding conductor installed by a licensed 

electrician.
Do not ground the appliance or appliance wiring to a 

• 

gas pipeline or to the neutral (white) power supply wire.
Do not install a fuse in the neutral or ground circuit.

• 

the dishwasher can be connected to:

A UL/CSA approved, grounded, three-prong receptacle (if 

local code permits). This method is the easiest to install.

OR

Directly to the house wiring. Hard-wire the dishwasher 

according to local code directly to a three wire grounded, 

single phase connection in a junction box.

NOtE:

 In either case, be sure the power cable or wire is 

long enough to remain connected when the appliance is 

removed from the cut-out for service.

If the electrical service does not meet the 

specifications above:

Have a licensed electrician prepare the electrical 

• 

receptacle or junction box for final connection inside the 

adjacent cabinet according to the specifications above.

Drain line 44" 

(1118 mm) long 

from chassis

strap

CL

 Hot water inlet

 Chassis strap

(do not remove)

   Back of

dishwasher

   Loop in 

drain hose,

do not remove

or change

5 1/2"

(140 mm) 

Power Supply Preparation

Summary of Contents for ED24

Page 1: ...Installation Instructions 24 Inch Dishwasher For use with models ED24 ID24 MDH24 MDV24 and PD24 Part No 101891 Rev L...

Page 2: ...completely and carefully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the lo...

Page 3: ...practices that COULD result in severe personal injury or death caution Hazards or unsafe practices that COULD result in minor personal injury or property damage DANGER To avoid the possibility of expl...

Page 4: ...after use Exercise caution when opening the door Let hot air and steam escape before looking or reaching inside Warning General Safety Precautions To reduce the risk of fire electric shock serious inj...

Page 5: ...6 mm 0 unless otherwise stated 23 7 8 60 6 cm Water Pressure 20 to 120 psi 138 827 kPa Water Temperature 120 F minimum Electrical Circuit Requirements 15 Amp 120 Vac 60 Hz dedicated grounded circuit T...

Page 6: ...ertop minimum dimensions shown below to insure safe operation Prepare the installation location as shown below All minimum product dimensions be must met or exceeded see page 3 Dimensions shown provid...

Page 7: ...nly by a licensed electrician as specified below It is the owner s responsibility to ensure that the electrical connection of this appliance is performed by a licensed electrician Electrical Specifica...

Page 8: ...liance Extended toe kick Left side access panel 6 Plastic fasteners for access panel Use and care manual Model ID24 only Integrated template screws and door tensioning springs for heavy door panels A...

Page 9: ...it prevent a short circuit condition by routing it on the ground under the unit and bringing the end up behind the junction box as shown below Doing so reduces the chance of shorts against the interna...

Page 10: ...in the side of the cut out Pull all of the slack out of the wire If the unit is to be connected directly to the house wiring With power turned off at the circuit breaker or fuse box remove the house j...

Page 11: ...of the cut out Remove the lower rack from the dishwasher and place 4 a level on the tank side wall rack guides to verify the unit is level front to back To verify left to right level place a level on...

Page 12: ...s through the 1 2 diameter access holes inside the dishwashing compartment on the ceiling and the sides near the front Make sure that the anchoring screws pass through the anti tip brackets located on...

Page 13: ...ach it before panel installation CAUTION To prevent corrosion and the possibility of the panel falling off use only stainless steel screws where instructed The provided mounting screws are designed fo...

Page 14: ...tee or disposal above the sink trap as shown below Tighten the holding clamp For installations with an 2 air gap check to make sure the drain line from the air gap to the disposal drain tee is connec...

Page 15: ...inutes then carefully open the door to verify water is filling the dishwasher tank If there is water present close the door and continue the process Should the water not fill the tank or the pump is n...

Page 16: ...Dacor Phone 800 793 0093 FAX 626 403 3130 www Dacor com...

Reviews: