2
Verifying the Package Contents
Verify that all required components have been
provided. If any item is missing or damaged,
please contact your dealer immediately. Do not
install a damaged or incomplete appliance.
• Mounting Screws
• Use & Care Videotape
• Oven Racks
• Broiler Grill and Pan
• Exhaust Grill/Lower Trim
• Rear Top Trim
Installation Planning
A qualified technician must complete the
installation of this built-in appliance. Proper
installation is your responsibility.
Carefully check the location where the oven is
to be installed. The oven should be placed for
convenient access, but away from drafts that
may be caused by doors, windows and HVAC
outlets. Make certain that electrical power can
be provided in the selected location.
Plan the installation so that all minimum
clearances are met or exceeded. Dimensions
shown provide minimum clearances, unless
otherwise noted. Be certain that proper
clearance is provided for the oven door when it
is in the open position.
The specified minimum cabinet depth and width
must be provided. The cabinet depth and width
must completely enclose the recessed portion of
the oven.
Cabinet cutout dimensions must be used as
indicated. All contact surfaces between the
appliance and the cabinet must be solid and
level. The oven support platform must be flush
with the bottom edge of the cabinet cutout.
Make certain that you have everything
necessary to ensure a proper installation before
proceeding.
NOTE:
All dimensional tolerances are
+ 1/16”, - 0” unless otherwise
stated.
Dacor
Model Number
Cutout Width
“A”
Cutout Height
“B”
Minimum Cabinet
Overall Depth
“C”
Minimum Cabinet
Width
“D”
ECS127
25 1/2”
(648mm)
27 3/8”
(695mm)
24”
(610mm)
27”
(686mm)
MCS127
ECS130
28 1/2”
(724mm)
30”
(762mm)
PCS130
MCS130
ECS136
34 1/2”
(876mm)
27 3/4”
(705mm)
36”
(914mm)
ECS227
25 1/2”
(648mm)
49 1/16”
(1246mm)
27”
(686mm)
MCS227
ECD227
MCD227
ECS230
28 1/2”
(724mm)
30”
(762mm)
PCS230
MCS230
ECD230
PCD230
MCD230
Cutout Dimensions
1 1/2" (38mm)
Typical counter top
36"
(915mm)
"A"
"C"
"B"
1
"D"
3"
4"
Electrical
access
3/4" (19mm)
Support platform
(flush with cutout)
1" (25mm) Minimum
to combustible floor
1
3/4" (19mm)
Support platform
(flush with cutout)
Recommended
electrical
access
1" (25mm) Min.
clear to top of
doors for heat
exhaust
9 5/8"
(244mm)
Recommended
(may be altered)**
"B"
3"
4"
"A"
24"
(610mm)
Minimum interior
cabinet depth
"D"
Alternate
electrical
access
2
31 1/4"
(794mm)
Recommended
(may be altered)
"B"
3"
24"
(610mm)
Min. interior
cabinet depth
"A"
3/4" (19mm)
Support platform
(flush with cutout)
4"
"D"
Alternate
electrical
access
1" (25mm) Min.
clear to top of
doors for heat
exhaust
1
2
Recommended
electrical
access
Single Wall Oven
Cutout Dimensions
Double Wall Oven
Cutout Dimensions
Single Wall Oven Installed under-counter
Cutout Dimensions
NOTE:
Electrical junction box may be
located:
1. Above the oven cutout, to the
right.
2. Below the oven platform, to