7
Installation Instructions
WARNING
If the electrical service provided does not meet the
•
Electrical Specifications
(see page 4), do not pro-
ceed with the installation. Call a licensed electrician to
correctly install the required wiring.
Failure to disconnect power prior to installation may
•
result in an electrical shock or fire hazard.
Do not turn on power to the appliance until the oven is
•
properly grounded according to these instructions.
The installer must connect the ground terminal (or
•
lead) on the appliance to a grounded, metallic, perma-
nent wiring system or grounding conductor. Failure to
do so may result in an electric shock hazard.
Do not install a fuse in the neutral or ground circuit. A
•
fuse in the neutral or ground circuit may result in an
electric shock hazard.
The appliance must be connected to the power supply
•
with copper wire only. The use of aluminum wire may
result in unsatisfactory conditions.
Electrical Connection
Connecting to a 4-Wire Electrical System
Separate the wires coming out of the appliance conduit.
1.
Connect the white wire from the appliance conduit to
2.
the white (neutral) supply wire in the junction box.
Connect the black wire from the appliance conduit to
3.
the black (L1) supply wire in the junction box.
Connect the red wire from the appliance conduit to the
4.
red (L2) supply wire in the junction box.
Connect the green wire from the appliance conduit to
5.
the green (ground) wire in the junction box.
Incoming
power
Wire nut,
4 places
Junction box
Conduit to
oven
IMPORtANt
Provide slack in the conduit to allow the oven to slide
•
forward for servicing.
The electrical connection leads from the supplied
•
appliance conduit may be a smaller gage than the
standard household wiring of the dedicated supply cir-
cuit. They are suitable for connection to household wir-
ing under the jurisdiction of the National Electric Code,
and/or the local inspection authority.
Before proceeding, turn off power to the junction box at
1.
the circuit breaker panel or fuse box.
Position the oven directly in front of the cabinet cutout.
2.
Feed the appliance conduit into the electrical junction
3.
box and attach it using a UL approved strain relief.
Depending upon local codes, utilize one of three meth-
4.
ods to connect the appliance to the electrical power:
Connect to a 4-wire electrical system
◊
Connect to a 3-wire electrical system with external
◊
ground, according to local codes.
Connect to a 3-wire electrical system, where local
◊
codes permit
Summary of Contents for DO130