PLANNING
GUIDE
5.15
Specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
Distinctive Range
DR30D
Note 2
E
F
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
1
Vertical to combustible surface from range grate level; if
installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
Non-combustible
surface along
back wall
recommended
10” (25.4 cm) Min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
Min.
1
37 7/8
(96.2 cm)
Max.
13” (33.0 cm)
Max.
4
18” (45.7 cm)
Min.
1, 4
Suggested
location of
utilities
3
4
Not applicable for cabinets more than a horizontal
distance of 10” (25.4 cm) from the edge of the range.
Cutout Dimensions
E
F
36” (91.4 cm)*
30” (76.2 cm)**
30
1
/
16
” (916mm)
* Recommended
** Minimum
gas and Electrical Service
■
The shaded area shown below denotes the location of the gas inlet
and the electrical junction box/receptacle. This is the recommended
location. For replacement purposes, the location of the existing
utilities may be utilized provided they do not interfere with the sides
or rear of the range. Check local building codes for permissible gas
valve locations.
■
An external manual shut-off valve must be installed between the gas
inlet and the range for the purpose of turning on or shutting off gas to
the appliance.
The installation must allow for the following:
■
Access to the gas shut-off valve when the unit is installed.
■
Access to the remote circuit breaker panel/fuse box when the range
is in place.
■
The gas supply piping, gas shut-off valve and the electrical junction
box or receptacle must be located so they do not interfere with the
range when it is installed.
■
The junction box and gas shut off valve must be located so that
the range can be pulled out for service while the appliance remains
connected.
Cabinet Layout
■
Carefully check the location where the range is to be installed. For
best performance, the range should be placed away from drafts that
may be caused by doors, windows and heating and air conditioning
outlets.
■
To reduce the risk of personal injury and to reduce accumulated
smoke in the room, Dacor strongly recommends installing a range
hood. A range hood should project horizontally a minimum of five (5)
inches beyond the face of the cabinets.
■
All maximum and minimum dimensions and clearances shown in the
diagram below must be maintained for safe operation.
■
The range may be installed flush to the rear wall. A non-combustible
rear wall is not mandatory, but Dacor highly recommends installing
a non-combustible material from the countertop level up to the vent
hood or installation of a backguard.
■
Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
REqUIRED cAbINEt DImENsIoNs
Cabinet tolerances: -1/16”, (+1.6mm) -0
Document # PG-006
Revised 10/01/11 Page 2/2